1
Maintenance schedule
User’s Information Manual
5
ƽ
ƽ WARNING
Follow the maintenance procedures given throughout this manual. Failure to perform the service and
maintenance or follow the directions in this manual could result in damage to the pool heater or system,
resulting in severe personal injury, death, or substantial property damage.
Service technician
(see the EnergyRite Service Manual for
instructions)
General:
• Address reported problems
• Inspect interior; clean and vacuum if
necessary
• Check for leaks (water, gas, and flue)
• Verify flue and air lines in good
condition and sealed tight
• Check control settings per the Access
Setup Menu in the EnergyRite Service
Manual
• Check ignition and flame sense
electrodes (sand off any deposits;
clean and reposition)
• Check wiring and connections
• Perform start-up checkout and
performance verification per Section 9
in the EnergyRite Installation and
Operation Manual.
• Flame inspection (stable, uniform)
If combustion or performance
indicate need:
• Clean burners
• Clean heat exchanger
ANNUAL
ST
ART
-UP
Owner maintenance
(see the following pages for instructions)
Daily
• Check pool heater area
Monthly
• Check vent piping
• Check air inlet piping (if
applicable)
• Check relief valve (if applicable)
Periodically
• Test low water cutoff (if used)
• Reset button (low water cutoff)
Every
6 months
• Check pool heater piping (gas
and water) for leaks
• Operate relief valve (if
applicable)
End
of season
• Shut the pool heater down and
winterize if location is subjected
to freezing temperatures, see the
Winterizing
section in the
EnergyRite Service Manual