beautypg.com

Energyrite control module – Lochinvar EnergyRite ER202 User Manual

Page 10

background image

User’s Information Manual

10

3

EnergyRite control module

Access modes

Modes of operation

There are three modes of operation: 1) Off, 2) Pool, and
3) Spa. The factory default mode is Off.

Off mode

When in Off Mode the control will display CONTROL OFF
and will not monitor any of the inputs.

Setup menu

Additional features can be accessed and adjusted through the
Setup Menu. Please reference the EnergyRite Service Manual
for a detailed description of the Setup Menu.

Service menu

Temperature rise and data logging information can be accessed
from the Service Menu. Please reference the EnergyRite Service
Manual for a detailed description of the Service Menu.

Status Display Screens

Display shows:

Description

Control: OFF

The control module has been placed in the Off Mode.

Pool: Standby

The unit has not received a call for heat.

Pool Temp = ***°F

Indicates the current inlet water temperature.

Pool Mode Prepurge

A call for heat has been initiated. The blower has been powered and
the air pressure switch has closed.

The prepurge period is 15

seconds.

Pool Mode Ignition

After the prepurge period, the unit has begun an 8 second spark
period to light the main burners.

Pool: Heating

The burners have fired and the flame has been detected.

Standby

Remote is active and has either satisfied the set point or there is no
call for heat from the remote.