TROUBLESHOOTING & REPAIR
F-104
F-104
COMMANDER 300
RETEST AFTER REPAIR
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine’s electrical characteristics. OR
• If you repair or replace any electrical components.
ENGINE OUTPUT
Mode
No Load RPM
Load RPM
Low Idle
1350 - 1400
NA
High Idle
1880 - 1919
1780 - 1820
WELDER DC (STICK) OUTPUT
Mode Selector
Fine Control
Open Circuit
Load Volts
Load Amps
Switch
Volts
30-375 Setting
Maximum
82-89
34-38
375-380
PIPE MODES SHORT CIRCUIT CURRENT
(FINE CONTROL AT MAXIMUM)
Selector Position
Short Circuit Current (Amps)
60
80-120
90
180-210
150
280-320
230
380-410
300
380-410
WELDER CV (WIRE) OUTPUT
Mode Selector
Fine Control
Open Circuit
Load Volts
Load Amps
Switch
Voltage
CV Mig/Mag
Maximum
61-64
40-46
370-380
CV Mig/Mag
Maximum
61-64
48-52
20
CV Mig/Mag
Minimum
28-32
11-14
20
AUXILIARY POWER OUTPUT
230 Volt Receptacle
115 Volt Receptacles
Open Circuit
Load Volts
Load Amps
Open Circuit
Load Volts
Load Amps
Voltage
Voltage
230 - 264
216-250
44
115 - 132
108 - 132
15