beautypg.com

Lennox Hearth Elite Series RDV-CK-LP TO NG User Manual

Page 4

background image

Step 14. Reinstall the the log set and glass door assembly. See Pages

10 and 11 (Log Set Installation) and Page 18 (Door Assembly

Installation) in the Installation and Operation Manual.

Step 15. Light the appliance per the lighting instructions label on appliance

(located below glass door) or lighting instructions on Page 13

in the Installation and Operation Manual. Inspect for proper

pilot and burner flame appearances. See Figures 11 and 12

or refer to Pages 15 and 17 of the Installation and Operation

Manual.

Figure 12 - Burner Flame Appearance

No Blue Flame

Center

Soot at

Flame Tip

Dark Orange

Flame

IMPROPERLY

BuRNING FLAME

Soot above

Flame Tip

No Soot at

Flame Tip

PROPERLY

BuRNING FLAME

Semi-Transparent

Yellow Flame

Blue Flame

Center

Ports on Pan

Burner Assembly

Figure 11 - Proper Pilot Flame Appearance

Inlet Gas Supply Pressure

Fuel #

Minimum

Maximum

Desired

Nat.

Gas

5" wC/po. C.E

(1.24 kPa)

10.5" wC/po. C.E

(2.61 kPa)

7" wC/po. C.E

(1.74 kPa)

Manifold Gas Supply Pressure

Fuel #

Low

High

Natural

Gas

(Lo) 1.7" wC/po. C.E

(0.42 kPa)

(Hi) 3.5" wC/po. C.E

(0.87 kPa)

Step 12. Turn on gas supply and test for gas leaks using a gas leak test

solution (see Test Procedure on Page 12 of the Installation and

Operation Manual).

Step 13. Using a manometer, test the inlet and manifold gas pressure

per instructions in the Installation and Operation Manual (Page

12) and as shown in the following 2 tables.

Step 11.

33,000 BTu

If you are using the #36 orifice, adhere the RDV 33 sticker

(provided) in place on the safety label as shown in Figure 9.

The safety label is located in the control compartment.

40,000 BTu (standard from factory)

If you are using the (standard) 1/8” orifice, the label will read

RDV 40 on the safety label as shown in Figure 10. The safety

label is located in the control compartment.

Safety Label

RDV 33 Sticker

RDV 40

Figure 9 - RDV 33 If #36 Orifice is Used

Safety Label

Figure 10 - RDV 40 If 1/8” Orifice is Used

4

Printed in u.S.A. © Lennox Hearth Products 2007

P/N 775,238M REV. A 12/2007

Lennox reserves the right to make changes at any time, without notice, in design,

materials, specifications, prices and also to discontinue colors, styles and products.

Consult your local distributor for fireplace code information.

1110 west Taft Avenue • Orange, CA 92865

NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT TO SCALE.