Table 11. The Homologation Testing and Debugging Commands (continued)
Name
Description
Value
Comments
%Txx V.22 1200 originate signaling
90
Set S37 = 5
V.22 1200 answer signaling
91
Set S37 = 5
V.22bis/V.34 2400 originate signaling*
90
Set S37 = 6
V.22bis/V.34 2400 answer signaling*
91
Set S37 = 6
V.32/V.34 4800 originate signaling*
90
Set S37 = 7
V.32/V.34 4800 answer signaling*
91
Set S37 = 7
V.32/V.34 7200 originate signaling*
90
Set S37 = 8
V.32/V.34 7200 answer signaling*
91
Set S37 = 8
V.32bis/V.34 9600 originate signaling*
90
Set S37 = 9
V.32bis/V.34 9600 answer signaling*
91
Set S37 = 9
V.32bis/V.34 12000 originate signaling*
90
Set S37 = 10
V.32bis/V.34 12000 answer signaling*
91
Set S37 = 10
V.32bis /V.3414400 originate signaling*
90
Set S37 = 11
V.32bis/V.34 14400 answer signaling*
91
Set S37 = 11
V.32ter/V.34 16800 originate signaling*
90
Set S37 = 12
V.32ter/V.34 16800 answer signaling*
91
Set S37 = 12
V.32ter/V.34 19200 originate signaling*
90
Set S37 = 13
V.32ter/V.34 19200 answer signaling*
91
Set S37 = 13
V.21 Channel 2 mark symbol
91
Set S37 = 3
V.21 Channel 2 space symbol
93
Set S37 = 3
V.27 2400 signaling
76
—
V.27 4800 signaling
77
—
V.29 7200 signaling
78
—
V.29 9600 signaling
79
—
V.17 12000 signaling
80
—
V.17 14400 signaling
81
—
Off-Hook
82
This puts the modem in off-hook state.
V.34 21600 originate signaling
90
Set S37 = 14
V.34 21600 answer signaling
91
Set S37 = 14
V.34 24000 originate signaling
90
Set S37 = 15
V.34 24000 answer signaling
91
Set S37 = 15
V.34 26400 originate signaling
90
Set S37 = 16
V.34 26400 answer signaling
91
Set S37 = 16
V.34 28800 originate signaling
90
Set S37 = 17
V.34 28800 answer signaling
91
Set S37 = 17
V.34bis 31200 originate signaling
90
Set S37 = 18
V.34bis 31200 answer signaling
91
Set S37 = 18
V.34bis 33600 originate signaling
90
Set S37 = 19
V.34bis 33600 answer signaling
91
Set S37 = 19
•
The default is V.34 with register S28 = 1. To disable, set S28 = 0.
The following example shows how to use the V.22bis 2400 originate signaling homologation test command:
S28 = 0
S37 = 6
AT%T90