\Tn

Inactivity Timer

This command specifies the length of time (in minutes) that the modem will wait before disconnecting when no
data is sent or received. A setting of zero disables the timer. Alternatively, this timer may be specified in register
S30. This function is only applicable to buffer mode.

\T0:

Inactivity timer disabled (default).

Result Codes:

OK

n = 0 - 255

ERROR

Otherwise

\Vn

Protocol Result Code

\V0:

Disable protocol result code appended to DCE speed.

\V1:

Enable protocol result code appended to DCE speed (default).

\V2:

Same as \V1.

Result Codes:
OK

n = 0, 1

ERROR

Otherwise

\Xn

XON/XOFF Pass Through

\X0:

Modem process XON/XOFF flow control characters locally (default).

\X1

Modem passes XON/XOFF flow control characters.

Result Codes:

OK

n = 0, 1

ERROR

Otherwise

-Cn

Data Calling Tone

Data Calling Tone is a tone of certain frequency and cadence as specified in V.25 which allows remote
Data/FAX/Voice discrimination. The frequency is 1300 Hz with a cadence of .5 s on and 2 s off.

-C0:

Disabled (default).

-C1:

Enabled.

Result Codes:

OK

n = 0, 1

ERROR

Otherwise

-V90 =

command to enable/disable V.90 and change downstream rate

-V90=0 will disable V.90
-V90=1 will enable V.90 Auto Rate (default value)
-V90=X - controls the downstream rate

-V90? - Shows the current value
-V90=? - Shows the range [0-21]