I/o map – Lynx EPM-4 User Manual
Page 45
Memory and I/O Map
EPM-4 Reference Manual
Reference – 37
I/O
M
AP
The following table lists the common I/O devices in the EPM-4 I/O map. User I/O devices should
be added in the 104h – 3FFh range, using care to avoid the devices already in the map as shown
below.
Table 9: On-Board I/O Devices
I/O Device
Standard
I/O Addresses
See ÉlanSC520 register set manual
000h-0FFh
Special Control Register
0E0h
Revision Indicator Register
0E1h
Map and Paging Control Register
0
E
3h
Primary IDE Controller
1
F
0h – 1
F
6h
COM 4 Serial Port
2
E
8h – 2
EF
h
COM 2 Serial Port
2F8h – 2F
F
h
COM 3 Serial Port
3E8h – 3EFh
Floppy Disk Controller
3
F
0h – 3
F
7h
COM1 Serial Port
3
F
8h – 3
F
Fh
CBAR FFFCh-FFFFh
Note:
I/O ports occupied by on-board devices are freed up when the device is disabled in
CMOS Setup.