beautypg.com

Caution, Variable speed drive programming, Programming the hitachi inverter – Linear VS-GSWG User Manual

Page 31

background image

VS-GSWG Swing Gate Operator Installation Guide

- 29 -

P1250 Revision X6 7-8-2011

Variable Speed Drive Programming

Programming the Hitachi Inverter

1. Apply power

2. Press FUNC

3. Use

▲▼ arrows to advance to F_ _ (F002 for L200)

4. Press FUNC arrow to get to F02 (L100 ONLY)

5. Press FUNC, arrows to change to 3.0 (3.00 for L200),

STR

6. Up arrow to advance to next parameter, (F03), FUNC

to view, arrows to change, STR to store and continue,
advance through listed parameters and store new values.

7. To switch from one letter prefi x to another, press FUNC

3 times, advance to desired letter prefi x, press FUNC,
advance to desired parameter.

8. When all parameters have been changed, advance to

D01, press FUNC, then press STR. This will display the
operating speed in Hz. (0-95)

CAUTION

This unit has been programmed at the factory. No changes
should be necessary for normal operation. PLEASE CONSULT
THE FACTORY BEFORE MAKING ANY CHANGES!

List of parameters set at factory

MODEL L100

MODEL L200

FUNCTION

DESCRIPTION

RECOMMENDED

SETTING

FUNCTION

DESCRIPTION

RECOMMENDED

SETTING

F02

ACCEL TIME

3.0

F002

ACCEL TIME

3.00

F03

DECEL TIME

3.0

F003

DECEL TIME

3.00

A01

SPEED SOURCE

00 (POT)

A001

SPEED SOURCE

00 (POT)

A02

RUN COMMAND SOURCE

01

A002

RUN COMMAND SOURCE

01

A04

MAX SPEED

95.0 (Hz)

A004

MAX SPEED

95 (Hz)

A20

TARGET SPEED

95.0 (Hz)

A020

TARGET SPEED

95.0 (Hz)

A21

SECOND SPEED

20.0 (Hz)

A021

SECOND SPEED

20.0 (Hz)

A042

AUTO TORQUE BOOST

0

A044

BOOST PERCENT

00

A081

AUTO VOLTAGE
REGULATION

01

A62

MIN SPEED

20.0 (Hz)

A062

MIN SPEED

20.0 (Hz)

B01

AUTO RESET

01

B001

AUTO RESET

01

B130

INHIBIT DECEL
OVERVOLTAGE

01

C03

TERM 3 FUNC

03

C003

TERM 3 FUNC

03

C04

TERM 4 FUNC

11

C004

TERM 4 FUNC

11

C014

TERM 4 STATE

01

Figure 14. Hitachi L200 Inverter

NOTE: L200 model

must have this switch in

the UP (SR) position.

NOTE: L200 model must

have these two switches

in the DOWN position.