Caution, Variable speed drive programming, Programming the hitachi inverter – Linear VS-GSWG User Manual
Page 31
VS-GSWG Swing Gate Operator Installation Guide
- 29 -
P1250 Revision X6 7-8-2011
Variable Speed Drive Programming
Programming the Hitachi Inverter
1. Apply power
2. Press FUNC
3. Use
▲▼ arrows to advance to F_ _ (F002 for L200)
4. Press FUNC arrow to get to F02 (L100 ONLY)
5. Press FUNC, arrows to change to 3.0 (3.00 for L200),
STR
6. Up arrow to advance to next parameter, (F03), FUNC
to view, arrows to change, STR to store and continue,
advance through listed parameters and store new values.
7. To switch from one letter prefi x to another, press FUNC
3 times, advance to desired letter prefi x, press FUNC,
advance to desired parameter.
8. When all parameters have been changed, advance to
D01, press FUNC, then press STR. This will display the
operating speed in Hz. (0-95)
CAUTION
This unit has been programmed at the factory. No changes
should be necessary for normal operation. PLEASE CONSULT
THE FACTORY BEFORE MAKING ANY CHANGES!
List of parameters set at factory
MODEL L100
MODEL L200
FUNCTION
DESCRIPTION
RECOMMENDED
SETTING
FUNCTION
DESCRIPTION
RECOMMENDED
SETTING
F02
ACCEL TIME
3.0
F002
ACCEL TIME
3.00
F03
DECEL TIME
3.0
F003
DECEL TIME
3.00
A01
SPEED SOURCE
00 (POT)
A001
SPEED SOURCE
00 (POT)
A02
RUN COMMAND SOURCE
01
A002
RUN COMMAND SOURCE
01
A04
MAX SPEED
95.0 (Hz)
A004
MAX SPEED
95 (Hz)
A20
TARGET SPEED
95.0 (Hz)
A020
TARGET SPEED
95.0 (Hz)
A21
SECOND SPEED
20.0 (Hz)
A021
SECOND SPEED
20.0 (Hz)
A042
AUTO TORQUE BOOST
0
A044
BOOST PERCENT
00
A081
AUTO VOLTAGE
REGULATION
01
A62
MIN SPEED
20.0 (Hz)
A062
MIN SPEED
20.0 (Hz)
B01
AUTO RESET
01
B001
AUTO RESET
01
B130
INHIBIT DECEL
OVERVOLTAGE
01
C03
TERM 3 FUNC
03
C003
TERM 3 FUNC
03
C04
TERM 4 FUNC
11
C004
TERM 4 FUNC
11
C014
TERM 4 STATE
01
Figure 14. Hitachi L200 Inverter
NOTE: L200 model
must have this switch in
the UP (SR) position.
NOTE: L200 model must
have these two switches