Troubleshooting (cont.)

Symptoms

Probable Causes

Recommended Action

1.

Remote control does not

work.

A.

Batteries improperly installed or

dead.

A.

Replace batteries.

B.

Antenna on wiring harness is

damaged.

B.

Replace wiring harness.

C.

Remote control not programmed

correctly.

C.

See homeowners guide or service

manual.

D.

Remote control does not work.

D.

Replace remote control.

E.

Control does not work.

E.

Replace control.

Backjet System

Symptoms

Probable Causes

Recommended Action

1.

Backjets do not operate.

A.

Whirlpool pump is not

operating.

A.

Turn on pump.

B.

Backjet butterfly valve does not

open.

B.

Check for loose connections or

wires leading from backjet pulse

canister to control. Replace backjet

pulse canister or control if

necessary. Refer to installer/dealer.

C.

Not enough water in whirlpool.

C.

Fill whirlpool so water level

sensors are covered.

D.

Actuator switch does not work.

D.

Replace actuator switch. Refer to

installer/dealer.

E.

Power from pump motor to

control is off.

E.

Check for loose connections or

wires leading from pump motor to

control. Refer to installer/dealer.

F.

Backjet pipe is blocked.

F.

Remove obstruction.

G.

Switch wire from switch to

control is disconnected.

G.

Reconnect or replace switch wires

that use modular plug. Refer to

installer/dealer.

2.

Backjets do not pulse.

A.

Pulse canister does not work.

A.

Check for loose connections or

wires leading from pulse canister to

control. Replace pulse canister or

control if necessary. Refer to

installer/dealer.

B.

Switch does not work.

B.

Replace switch. Refer to

installer/dealer.

C.

Switch wire from switch to

control is disconnected.

C.

Reconnect or replace switch wires

that use modular plug. Refer to

installer/dealer.

Neckjet System

Symptoms

Probable Causes

Recommended Action

1.

Keypad does not respond

when neckjet mode is

selected.

A.

User keypad does not work.

A.

Replace user keypad.

2.

Pump operates but

neckjets do not turn on.

Indicator bar on user

keypad is flashing.

A.

Pillow is not installed.

A.

Make sure the pillow is properly

attached to the neckjet body.

B.

Reed switch does not work.

B.

Check reed switch wiring and

replace if necessary.

C.

Wiring harness from neckjet to

control is loose, disconnected or

damaged.

C.

Check wiring for proper

connections. Replace wiring

harness if necessary.