beautypg.com

Figure 6-4. typical location and mounting – Kohler 3.5CFZ User Manual

Page 65

background image

TP-5695 12/93

Installation 6-3

TOTAL HOURS

0

0 0

0

0

1/10

10A

FUSE

BATT.

CHRG.

INPUT

NOTE

Use two hose clamps on each end of

all flexible exhaust hose connections.

*Indicated components must conform to U.S.C.G. Regulations.

4

*5

6

7

8

*9

10

11

STOP/START

258000-D

2

1

13

*14

12

3

1. Heat Exchanger
2. Siphon Break (See Instruction Sheet TT-927 for

Proper Installation.)

3. Exhaust Mixer
4. Engine-Driven Seawater Pump
5. Exhaust Hose
6. Seawater Strainer
7. Raw Waterline

8. Intake Through-Hull Strainer
9. Seacock

10. Mounting Base

11. Mounting Tray

12. Coolant Recovery Tank
13. Hose Clamp
14. Fuel Line

Figure 6-4. Typical Location and Mounting