Adjustment – Kenwood TK-862G User Manual
Page 25
25
ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
TK-860G/862G
9. QT deviation 1) Set test mode
Power meter Rear
ANT
Front
CH /
0.75kHz
±
50Hz (Wide/Narrow)
• Wide
Select “FQT” in tuning mode. Deviation
panel
panel
“_.FQT”
meter
Deviation meter filter
Oscilloscope
LPF : 3kHz
HPF : OFF
AF VTVM
Front
MIC
PTT : ON
AG
panel
Adjust [***]
2) “_.F.Q.T”
PTT : ON
Adjust [***]
3) “_.F.Q.T._.”
PTT : ON
Adjust [***]
• Narrow
4) “_FQT***.”
0.35kHz
PTT : ON
Adjust [***]
10. DQT
1) Set test mode
Front
CH /
0.75kHz
±
50Hz (Wide/Narrow)
deviation
Select “FDQT” in tuning mode.
panel
• Wide
“F.DQT”
Deviation meter filter
LPF : 3kHz
HPF : OFF
PTT : ON
Adjust [***]
2) “F.D.Q.T”
PTT : ON
Adjust [***]
3) “F.D.Q.T._.”
PTT : ON
Adjust [***]
• Narrow
4) “FDQT***.”
0.35kHz
PTT : ON
Adjust [***]
11. DTMF
1) Set test mode
Front
CH /
3.0kHz
±
0.2kHz
deviation
Select “DTMF” in tuning mode.
panel
• Wide
Deviation meter filter
LPF : 15kHz
HPF : OFF
PTT : ON
Adjust [***]
• Narrow
2) “DTMF***.”
1.5kHz
±
0.1kHz
PTT : ON
Adjust [***]
12. TONE
1) Set test mode
Front
CH /
3.0kHz
±
0.1kHz (Wide/Narrow)
deviation
Select “TONE” in tuning mode.
panel
• Wide
Deviation meter filter
LPF : 15kHz
HPF : OFF
PTT : ON
Adjust [***]
• Narrow
2) “TONE***.”
1.5kHz
PTT : ON
Adjust [***]