Adjustment – Kenwood TK-862G User Manual
Page 24
ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
24
TK-860G/862G
6. Modulation
1) Set test mode
Power meter Rear
ANT
Front
CH /
Make the de-
(Wide/Narrow)
balanced
MIC input : OFF
Deviation
panel
panel
modulation
• Wide
Select “BAL” in tuning mode. meter
waveform neat.
“_.BAL”
Oscilloscope
Deviation meter filter
LPF : 3kHz
AF VTVM
Front
MIC
HPF : OFF
AG
panel
De-emphasis : OFF
PTT : ON
Adjust [***]
2) “_.B.A.L”
PTT : ON
Adjust [***]
3) “_.B.A.L._.”
PTT : ON
Adjust [***]
• Narrow
4) “_BAL***.”
PTT : ON
Adjust [***]
7. Maximum
1) Set test mode
3.95kHz (Wide)
±
50Hz (Wide/Narrow)
deviation
Connect AG to the MIC
1.75kHz (Narrow)
• Wide
terminal.
(According to the
Select “MAX” in tuning mode.
larger +, –)
“_.MAX”
AG : 1kHz/50mV
Deviation meter filter
LPF : 15kHz
HPF : OFF
De-emphasis : OFF
PTT : ON
Adjust [***]
2) “_.M.A.X”
PTT : ON
Adjust [***]
3) “_.M.A.X._.”
PTT : ON
Adjust [***]
• Narrow
4) “_MAX***.”
PTT : ON
Adjust [***]
8. MIC
1) Set test mode
Check
±
3kHz
±
0.2kHz (Wide)
seisitivity
CH : CH1 - Sig1
±
1.5kHz
±
0.05kHz (Narrow)
check
AG : 1kHz/5mV
PTT : ON
Adjust [***]