beautypg.com

Color balance, Exposure table - daylight illumination, Reciprocity characteristics – Kodak H-1-5205T User Manual

Page 2: Processing, Identification, Laboratory aim densities (lad), Lighting contrast

background image

2

KODAK VISION2 250D Color Negative Film 5205 / 7205

H-1-5205t

COLOR BALANCE

These films are balanced for exposure with daylight
illumination (5500 K). For other light sources, use the
correction filters in the table below.

1

These are approximate corrections only. Make final corrections during

printing.

2

These are starting-point recommendations for trial exposures. If the kind

of lamp is unknown, a KODAK Color Compensating Filter
CC20M + CC10B can be used with an exposure index (EI) of 125.

Note: Consult the manufacturer of high-intensity ultraviolet
lamps for safety information on ultraviolet radiation and
ozone generation.

EXPOSURE TABLE - DAYLIGHT
ILLUMINATION

At 24 frames per second (fps), 170-degree shutter opening:

Use this table for average subjects that contain a

combination of light, medium, and dark colors. When a
subject includes only pastels, use at least 1/2 stop less
exposure; dark colors require 1/2 stop more exposure.

Lighting Contrast -

The recommended ratio of key-light-plus-fill-light to fill
light is 2:1 or 3:1. However, you may use 4:1 or greater
when a particular look is desired.

Light Source

KODAK Filters on

Camera

1

Exposure

Index

Daylight (5500 K)

None

250

Tungsten (3000 K)

WRATTEN Gelatin

No. 80A

64

Tungsten (3200 K)

WRATTEN Gelatin

No. 80A

64

Tungsten
photoflood(3400 K)

WRATTEN Gelatin

No. 80A

64

White-Flame Arcs

Color

Compensating Filter

CC20Y + CC10C

160

Yellow-Flame Arcs

Color

Compensating Filter

CC30C + CC10M

160

OPTIMA 32

WRATTEN Gelatin

No. 80A

64

VITALITE

None

250

Fluorescent, Cool
White

2

Color

Compensating Filter

CC20M

200

Fluorescent, Deluxe
Cool White

2

WRATTEN Gelatin

No. 82C

160

Metal Halide

None

250

Lens
Aperture

f/1.4

f/2

f/2.8

f/4

f/5.6

f/8

f/11

f/16

Footcandles
Required

10

20

40

80

160

320 640 1250

RECIPROCITY CHARACTERISTICS

You do not need to make any filter corrections or exposure
adjustments for exposure times from 1/1000 to 1/10 second.
If your exposure is in the 1-second range, it is recommended
that you increase your exposure

2

3

stop and use a KODAK

Color Compensating Filter CC10R. If your exposure is in the
10 second range, it is recommended that you increase your
exposure by a stop and use a KODAK Color Compensating
Filter CC10R.

PROCESSING

Process ECN-2

Most commercial motion-picture laboratories provide a

processing service for these films. See KODAK Publication
No. H-24.07, Processing KODAK Color Negative Motion
Picture Films, Module 7
available online at http://
www.kodak.com/US/plugins/acrobat/en/motion/support/
processing/h247/h2407.pdf, for more information on the
solution formulas and the procedure for machine processing
these films. There are also pre-packaged kits available for
preparing the processing solutions. For more information on
the KODAK ECN-2 Kit Chemicals, check Kodak's Motion
Picture Films price catalog.

IDENTIFICATION

After processing, the product code numbers 5205 (35 mm
and 65 mm) or 7205 (16 mm), emulsion and roll number
identification, KEYKODE numbers, and internal product
symbol (EQ) are visible along the length of the film.

LABORATORY AIM DENSITIES (LAD)

To maintain optimum quality and consistency in the final
prints, the laboratory must carefully control the color timing,
printing, and duplicating procedures. To aid in color timing
and curve placement, negative originals should be timed
relative to Laboratory Aim Density (LAD) Control Film
supplied by Eastman Kodak Company.

1

The LAD Control

Film provides both objective sensitometric control and
subjective verification of the duplicating procedures use by
the laboratory.

In the LAD Control Method,

2

the electronic color analyzer

used for color timing is set-up with the LAD Control Film to
produce a gray video display of the LAD patch,
corresponding to 1.0 neutral density (gray) on the print. The
negative printing original is then scene-to-scene timed.
There are specific LAD values for each type of print or
duplicating film that the original can be printed on. For print
films, the LAD patch is printed to a neutral gray of 1.0 visual
density. For duplicating films, the specified aims are at the
center of the usable straight-line portion of the sensitometric
curve of the film.

1.Direct any inquiries to one of the regional sales offices.
2.Use of the LAD Control Method is described in the paper, "A Simplified

Motion-Picture Laboratory Control Method for Improved Color
Duplication," by John P. Pytlak and Alfred W. Fleischer in the October
1976 SMPTE Journal.