ELECTRICAL FEEDER CABLE

CONNECTION

To connect the supply cable:

- Remove the screws securing the

cover “A” on the rear of the cooker
(fig. 11.2).

- Feed the supply cable through the

cable clamp “D”. The supply cable
must be of a suitable size for the cur-
rent requirements of the appliance;
see the section “Feeder cable section”
(fig. 11.2).

- Connect the wires to the terminal

block “B” as shown in the diagram in
figure 11.3; or connect the phase
wires to the terminal block “B” and the
earth wire to the terminal PE as
shown in figure 11.2.

- Take up any slack in the cable and

secure with the cable clamp “D”.

- Replace the cover “A”.

N.B. The earth conductor must be left
about 3 cm longer than the others.

Fig. 11.2

D

B

PE

A

;;;

;;;

;

;

;

;

;

;

;

;

;

;;

N

L

FEEDER CABLE SECTION TYPE

HO5RR-F

230 V

3 x 0,75 mm

2

230 V

PE

N

L

1

(L

2

)

Fig. 11.3

PE Earth
N

Neutral

L

Live