beautypg.com

Table for the choice of the injectors, 2h3+ i – Kenwood CK 300 User Manual

Page 36

background image

36

TABLE FOR THE CHOICE OF THE INJECTORS

Cat:

II

2H3+

I

NCREASE OF AIR NECESSARY FOR GAS COMBUSTION

(2 m

3

/h x kW)

BURNERS

Air necessary for combustion [m

3

/h]

Auxiliary (A)

2,00

Semi-rapid (SR)

3,50

Rapid (R)

6,00

Triple-ring

7,00

Left Oven

7,40

Left Grill

5,00

Right Oven

4,40

Right Grill

4,00

BURNERS

Auxiliary (A)

1,00

0,30

27

50

-

adjustable

72 (X)

-

Semi-rapid (SR)

1,75

0,45

32

65

-

adjustable

97 (Z)

-

Rapid (R)

3,00

0,75

42

85

-

adjustable

115 (Y)

-

Triple-ring (TR)

3,50

1,50

65

95

-

adjustable

135 (T)

-

Left Oven

3,70

0,75

42

92

fully open* adjustable

140

5 *

Left Grill

2,50

-

-

80

fully open*

-

120

4 *

Right Oven

2,20

0,63

39

72

fully open* adjustable

110

4 *

Right Grill

2,00

-

-

70

fully open*

-

105

2 *

Nominal

Power

[kW]

Reduced

Power

[kW]

G 30 - 28-30 mbar

G 31 - 37 mbar

G 20

20 mbar

By-pass

[1/100 mm]

By-pass

[1/100 mm]

Ø injector

[1/100 mm]

Ø injector

[1/100 mm]

GB

*

= Reference value

Ring opening

[mm]

Ring opening

[mm]