ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark
1.BPF Wave
TEST CH:Center
SSG
ANT
Programming
RSSI MAX
form ADJ
Low
DVM
RSSI
Software:KPG-82D
Low’
Oscilloscope
Center
AF VTVM
High’
High
SSG otuput:–103 dBm(1.58µV)
2.Sesitivity
TEST CH:Center
ANT
Check
12dB SINAD or
check
Low
more
[Wide]
Low’
Center
High’
High
SSG otuput:–117 dBm(0.3µV)
SSG MOD:3kHz
3.Sesitivity
TEST CH:Center
Check
12dB SINAD or
check
SSG otuput:–115 dBm(0.4µV)
more
[Narrow]
SSG MOD:1.5kHz
4.Squelch
TEST CH:Low
Programming
write
Squelch open
threshold
SSG otuput:–122 dBm(0.18µV)
Software:KPG-82D
writing
SSG MOD:3.0kHz
[Wide]
5.Squelch
TEST CH:Center
Squelch open
threshold
SSG otuput:–120 dBm(0.22µV)
writing
SSG MOD:1.5kHz
[Narrow]
6.Squelch
TEST CH:High
Squelch open
tight
SSG otuput:–117 dBm(0.3µV)
writing
SSG MOD:3.0kHz
[Wide]
7.Squelch
TEST CH:Center
Squelch open
tight
SSG otuput:–116 dBm(0.35µV)
writing
SSG MOD:1.5kHz
[Narrow]
8.RSSI writing TEST CH:Center
[Wide]
SSG otuput:–123 dBm(0.16µV)
SSG MOD:off
9.RSSI writing TEST CH:Center
[Narrow]
SSG otuput:–122 dBm(0.18µV)
SSG MOD:off
Receiver Section
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Terminal
Parts
Method
Remark
15.BATT
1) BATT terminal voltage:5.5V Power meter
ANT
Check
Blinking of LED
Detection
PTT:ON
DVM
BATT terminal
Check
2) BATT terminal voltage:7.5V
No blinking of
PTT:ON
LED