Printheads

Printheads are replaceable components that connect to PICs through
a simple slide-on mechanism. With the DS9100 and DS9050 Systems,
you can stitch up to two printheads together for a total print width of
17.92 inches (455 cm).

Printhead physical specifications

Height:

5.5" (14 cm) print array

Width:

8.96" (22.76 cm)

Depth:

3.5" (8.9 cm)

Length:

12" (30.5 cm)

Weight:

14 lbs. (5.9 kg)

Resolution: DS9100: 300 x 300 dpi

DS9050: 300 x 300, 300 x 600 dpi

Printhead Interface Controller (PIC) Function

Each print station supports one or two Printhead Interface Controllers
(PICs). A PIC box contains the electronics, software and fluidics for
driving a single inkjet printhead. PIC physical specifications

Height:

14" (35.6 cm)

Width:

13" (33 cm)

Depth:

9.5" (24.1 cm)

Weight:

32 lbs. (14.5 kg)

Print station function

A print station houses the electronics and software that manage the
pumps, valves and filters that control the flow of ink, replenisher and
cleaning fluids for the continuous inkjet Kodak Versamark Printheads.
It also controls various physical properties of fluids—including
temperature, pressure and ink concentration.

Print station physical dimensions

Height:

29" (73.7 cm)

Width:

20" (50.8 cm)

Depth:

32" (81.3 cm)

Weight:

300 lbs. (136 kg)

Power:

200-240 VAC 50/60 Hz 30 amps

Umbilicals

PICs connect to the body of the print station through three umbilicals.
Electrical umbilical:
– Length:

40 feet (12.2 m)

– Diameter:

1.5" (3.8 cm)

– Weight:

35 lbs. (15.9 kg)

Fluidics umbilical:
– Length:

40 feet (12.2 m)

– Diameter:

1.5" (3.8 cm)

– Weight:

12 lbs. (5.4 kg)

Heated umbilical:
– Length:

40 feet (12.2 m)

– Diameter:

1.5" (3.8 cm)

– Weight:

12 lbs. (5.4 kg)

– Fluid capacity

(internal) Ink:

1 gal. (4-4.5 liters)

– Cleaner:

1/2 gal. (2 liters)

– External reservoir (optional)
– Capacity:

55 gal. (220 liters)

Environmental operating ranges

For environments with relative humidity: 10%–90% non-condensing, the
temperature range is: 60°F–85°F (15.6°C–29.4°C)

For environments with relative humidity: 10%–60% non-condensing, the
temperature range is: 86°F–104°F (30°C–40°C)

To learn more about solutions from Kodak:

Visit: graphics.kodak.com

Or in North America, call +1-866-563-2533

Printed using Kodak Technology.