Checking/replacing the flat pleated
filter

(Order no. 6.414-498)

Regularly check the flat pleated filter for damage.
If the flat pleated filter is damaged, replace it
immediately, otherwise the motor may be damaged.

!

Switch the unit off and open the cover on the
filter compartment.

!

Remove the flat pleated filter and replace with
a new one. Close the cover.

Checking and cleaning the
accessories

!

Check the nozzle, suction hose and suction
tube for blockages. They can be cleaned by
rinsing with water. Leave them to dry before
using.

Storing the vacuum cleaner

!

Switch the machine off.

!

Pull out the mains cable.

Note: Pull out the mains cable by the plug. Never tug
the cable.

If you have been working in wet-vacuuming
mode:

!

Empty the dirt container, rinse the inside
if required and leave to dry.

If you have vacuumed up viscous liquids:

!

Rinse the accessory.

!

Place the suction tubes and accessories in the
accessory bracket.

Technical Specifications

Mains connection

220–240 V

(AUS)

240 V

1~50,60 Hz

Fuse protection (surge-proof)

10 A

Power (suction motor)

P

max

1200 Watt

P

nom

1000 Watt

Air flow rate

68 l/s

Vacuum

200 mbar

Capacity

18 l

Max. water capacity

12 l

Length

390 mm

Width

290 mm

Height

490 mm

Weight without accessories

6 kg

Nominal width, accessory

Ø 35 mm

Sound level

72 dB(A)

Class of protection

II

Cable length

5 m

2.

2.

1.

1.