10
Cleaning Stainless Steel Baffle Filter
CAUTION
: DRAIN OIL BEFORE RESIDUE CAN OVERFLOW.
1. Grasp knob on baffle filter and push filter toward rear .
2. Gently pull each baffle filter down and discard oil and residue.
3. Wash baffle filters with warm soapy water.
4. Dry thoroughly and put back.
NOTE: Baffle Filters are top rack dishwasher safe.
Figure 13
Replacing Light Bulb
CAUTION
:
HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL.
1. Make sure all controls are OFF, and range hood is unplugged.
2. Place a flat-head screwdriver into the groove between the halogen light glass covering
and the housing .
3. Gently separate glass covering from the housing .
4. Gently pull out the defective light bulb
and discard. Light bulb should be 12V 20W
maximum.
5. Wear a glove or use a cloth to hold the new light bulb and push securely into light
socket. NOTE: DO NOT PUSH TOO HARD OR YOU MAY BREAK THE BULB
CONNECTOR.
6. Put back halogen light glass cover .
7. Plug back power cord and turn on range hood to test for operation.
1
2