Mechanized processing – Kodak CGP User Manual
Page 3
NOTE: It is recommended that the manufacturer of the pulsed-xenon or quartz-halogen lamps be
consulted for safety information pertaining to ultraviolet radiation and ventilation requirements due to
ozone generation.
Mechanized Processing
NOTE: Contamination of the developer with small amounts of fixer may result in speed or density loss.
Notice: Observe precautionary information on products labels and on the Material Safety Data Sheets.
The recommended starting point for optimum results for optimum results using
Kodak RA 2000
developer and replenisher (1:2) are:
Deep-Tank Processors
120 seconds at 75° F (24° C)
105 seconds at 80° F (27° C)
90 seconds at 85° F (30° C)
Rapid-Access Processors
30 seconds at 95° F (35° C)
Use a fixer such as
Kodak RA 3000 fixer and replenisher.
As a starting point, do not add hardener to the fixer. However, if abrasion or any other transport problems
occur in processing, add 3.2 oz of
Kodak RA 3000 fixer, part B (hardener) per working-strength gallon of
fixer. Add part B following recommended instructions (slowly and mixing thoroughly).
© Kodak, 2006. Kodak, Estar, and Wratten are trademarks of Kodak.