Electrical connections for 3-wire system, Electrical connections for 4-wire system – Kenmore 417.64182300 User Manual
Page 2
7
STRAIN
RELIEF
MOUNTING
BRACKET
NUT
TIGHTEN
NUT
TO THESE
THREADS
POWER
CORD
RED
WHITE
BLACK
TERMINAL BLOCK
SILVER TERMINAL
GREEN
GROUND
SCREW
GREEN POWER CORD
GROUND WIRE
GREEN
NEUTRAL
GROUND
WIRE
4. Thread a U.L. listed 30 amp power cord, NEMA 14-30
type ST or SRDT through the strain relief.
5. Attach the green power cord ground wire to the cabinet
with the green ground screw.
6. Attach the white (neutral) power cord conductor from the
power cord and the green ground wire from the dryer
harness (removed from the ground screw in step 3) to the
silver-colored center terminal on the terminal block. Tighten
the screw securely.
7. Attach the red and black power cord conductors to the
outer brass-colored terminals on the terminal block.
Do not make a sharp bend or crimp wiring/
conductor at the connections.
8. Tighten the screws securing the cord restraint firmly
against the power cord.
9. Tighten the strain relief nut securely so the strain relief
does not turn.
10. Reinstall the terminal block access cover.
TYPICAL 4
CONDUCTOR CORD
RED 240V
BLACK 240V
WHITE NEUTRAL
GREEN GROUND
30 AMP NEMA 14-30 TYPE SRDT OR ST
TYPICAL 4
CONDUCTOR
RECEPTACLE
POWER CORD
TIGHTEN NUT
TO THESE
THREADS
STRAIN
RELIEF
MOUNTING
BRACKET
GREEN
GROUND
SCREW
NUT
SILVER TERMINAL
GREEN
NEUTRAL
GROUND
WIRE
ELECTRICAL CONNECTIONS
FOR 3-WIRE SYSTEM
ELECTRIC Dryer
1. Remove the screws securing the terminal block access
cover and the strain relief mounting bracket located on the
back of the dryer upper corner.
2. Install a U.L. listed strain relief into the power cord entry
hole of the mounting bracket. Finger tighten the nut only at
this time.
3. Thread a U.L. listed 30 amp. power cord, NEMA 10-30
Type SRDT, through the strain relief.
4. Attach the power cord neutral (center wire) conductor to
the silver colored center terminal on the terminal block.
Tighten the screw securely.
5. Attach the remaining two power cord outer conductors to
the outer brass colored terminals on the terminal block.
Tighten both screws securely.
Do not make a sharp bend or crimp wiring/
conductor at connections.
6. Reattach the strain relief mounting bracket to the back of
the dryer with two screws. Tighten screws securely.
7. Tighten the screws securing the cord restraint firmly against
the power cord.
8. Tighten the strain relief nut securely so that the strain relief
does not turn.
9. Reinstall the terminal block cover.
ELECTRICAL CONNECTIONS
FOR 4-WIRE SYSTEM
ELECTRIC Dryer
1. Remove the screws securing the terminal block access
cover and the strain relief mounting bracket located on
the back of the dryer upper corner.
2. Install a U.L. listed strain relief in the entry hole of the
mounting bracket. Finger tighten the nut only at this time.
3. Remove the green neutral ground wire from the green