beautypg.com

Troubleshooting – Karcher K 3.97 M User Manual

Page 11

background image

11

TROUBLESHOOTING

Disconnect the machine from the power source before making any repair.

Symptom

Symptom

Symptom

Symptom

Symptom

Motor will not start

Unit does not reach high
pressure.

Output pressure varies high
and low.

Cause

Cause

Cause

Cause

Cause

On/Off switch is in the “OFF” (O)
position.

Power cord is not plugged in.

Extension cord is too long.
Extension cord is not proper gauge.
Extension cord is damaged.

Electrical outlet does not supply
adequate power.

Ground Fault Circuit Interrupter
(GFCI) tripped.

Diameter of garden hose is too
small.

Water supply is restricted.

Not enough inlet water supply.

Water inlet filter is clogged.

Quattro Nozzle is in low
pressure position.

Wash brush is attached.

Not enough inlet water supply.

Pump is sucking air.

Water inlet filter is clogged.

Discharge nozzle is obstructed.

Calcified gun, hose or Quattro
Nozzle.

Solution

Solution

Solution

Solution

Solution

Turn switch to the “ON” (I)
position

Plug in power cord.

Replace extension cord with either
“a 25 ft. 12/3 gauge cord or a 50
ft. 10/3 gauge cord.

Try a different outlet.

Reset breaker (power supply) or
GFCI.

Replace with a 3/4 inch garden
hose.

Check garden hose for kinks,
leaks and blockage.

Open water source full force.

Remove filter and rinse out in
warm water.

Turn Quattro Nozzle to high
pressure position.

Attach Quattro Nozzle.

Turn water on full force. Check
garden hose for kinks, leaks or
blockage.

Check that hoses and fittings are
air tight. Turn off machine and
purge pump by squeezing trigger
gun until a steady flow of water
emerges through the nozzle.

Remove filter and rinse out in
warm water.

Blow out or remove debris with a
fine needle.

Run distilled vinegar through
detergent suction tube.