beautypg.com

Product data sheets – KITCHENAID 2215851A User Manual

Page 16

background image

16

PRODUCT DATA SHEETS

Base Grille Water Filtration System Model WF-LC400/LC400

Capacity:

400 Gallons (1514 Liters)

Service Flow Rate:

0.5 GPM (1.89 L/min.) @ 60 psi.

It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.

Model WF-LC400 The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter’s rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter’s rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge LC400,
part# 4396164. 2001 suggested retail price of $39.95 U.S.A./
$49.95 Canada.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.

Refer to the “Front cover” or “Assistance or Service” section
for the Manufacturer’s name, address and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited
warranty.

Application Guidelines/Water Supply Parameters

*Test requirement is at least 100,000 particles/ml of AC Fine Test Dust. **Cyst performance is % reduction based on NSF Standard 53. ***Test
requirement is 0.15 mg/L ± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
® NSF is a registered trademark of NSF International.

Substance Reduction
Aesthetic Effects

Chlorine Taste/Odor
Particulate

U.S. EPA
MCL

N/A
N/A

Average
Influent

2.0 mg/L
610,000/mL*

Maximum
Effluent

N/A
N/A

Average
Effluent

0.04 mg/L
154/mL

Minimum %
Reduction

N/A
N/A

Average %
Reduction

98%
99%

NSF Test
Number

994707
994711

Contaminant
Reduction

U.S. EPA
MCL

Average
Influent

Maximum
Effluent

Average
Effluent

Minimum %
Reduction

Average %
Reduction

NSF Test
Number

Cyst
Turbidity

99.95%**
0.5 NTU

89,250/mL*
29 NTU

6/mL
0.12 NTU

2.3/mL
0.09 NTU

99.993%
99.59%

99.997%
99.69%

994710
994710

Lead

: @ pH 6.5

Lead

: @ pH 8.5

0.015 mg/L
0.015 mg/L

0.16 mg/L***
0.16 mg/L***

0.001mg/L
0.002 mg/L

0.001 mg/L
0.001 mg/L

99.4%
98.8%

99.4%
99.4%

994708
994709

Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.

Water Supply
Water Pressure
Water Temperature

City or Well

30 - 120 psi (207 - 827 kPa)

33° - 100°F (0.6° - 37.8° C)