Product data sheets – KITCHENAID 2215851A User Manual
Page 16
16
PRODUCT DATA SHEETS
Base Grille Water Filtration System Model WF-LC400/LC400
Capacity:
400 Gallons (1514 Liters)
Service Flow Rate:
0.5 GPM (1.89 L/min.) @ 60 psi.
■
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
■
Model WF-LC400 The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter’s rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter’s rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge LC400,
part# 4396164. 2001 suggested retail price of $39.95 U.S.A./
$49.95 Canada.
■
The product is for cold water use only.
■
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
■
Refer to the “Front cover” or “Assistance or Service” section
for the Manufacturer’s name, address and telephone number.
■
Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
*Test requirement is at least 100,000 particles/ml of AC Fine Test Dust. **Cyst performance is % reduction based on NSF Standard 53. ***Test
requirement is 0.15 mg/L ± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
® NSF is a registered trademark of NSF International.
Substance Reduction
Aesthetic Effects
Chlorine Taste/Odor
Particulate
U.S. EPA
MCL
N/A
N/A
Average
Influent
2.0 mg/L
610,000/mL*
Maximum
Effluent
N/A
N/A
Average
Effluent
0.04 mg/L
154/mL
Minimum %
Reduction
N/A
N/A
Average %
Reduction
98%
99%
NSF Test
Number
994707
994711
Contaminant
Reduction
U.S. EPA
MCL
Average
Influent
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
NSF Test
Number
Cyst
Turbidity
99.95%**
0.5 NTU
89,250/mL*
29 NTU
6/mL
0.12 NTU
2.3/mL
0.09 NTU
99.993%
99.59%
99.997%
99.69%
994710
994710
Lead
: @ pH 6.5
Lead
: @ pH 8.5
0.015 mg/L
0.015 mg/L
0.16 mg/L***
0.16 mg/L***
0.001mg/L
0.002 mg/L
0.001 mg/L
0.001 mg/L
99.4%
98.8%
99.4%
99.4%
994708
994709
Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.
Water Supply
Water Pressure
Water Temperature
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8° C)