Nighthawk Carbon Monoxide Alarm
AC Powered, Plug-in with Battery Backup
and Digital Display

Part Number 900-0234
Model KN-COP-DP-LS

1016 Corporate Park Drive, Mebane NC 27302
1-800-880-6788
www.kidde.com

Architectural and Engineering
Specifications

The carbon monoxide alarm shall be Kidde Unit Number KN-

COP-DP-LS (part number 900-0234) or approved equal. It shall be
powered by a 120VAC, 60 Hz source along with a 9V battery back
up. The temperature operating range shall be between 40°F and
100°F (4°C and 38°C) and the humidity operating range shall be
10% - 95% relative humidity.

The CO sensor shall be of a fuel cell design and shall meet

the sensitivity requirements of Underwriters Laboratories UL2034
Single and Multiple Station Carbon Monoxide Alarms. The unit
shall provide accuracy of ± 30% when reading CO concentration
levels.

The alarm shall include an integral plug that can be installed in

any outlet following the UL/NFPA/Manufacturer’s recommended
guidelines. The AC blades remain vertical independent of whether
the electrical socket is mounted vertically or horizontally. The
unit shall incorporate a digital display that meets the sensitivity
requirements of UL 2034. The display will identify the levels of
CO in parts per million (ppm) once that level reaches 30ppm (i.e.:
“abnormal” levels). The display will have a red dot in the lower
right corner that will blink to indicate the normal operation.

The alarm shall include a test/reset button. If pressed and re-

leased during normal operation, it shall electronically simulate the
presence of CO and cause the unit to go into alarm. This sequence
tests the unit’s electronics to ensure proper operation. If pressed
during alarm mode, the unit will be silenced and will begin moni-
toring CO levels again.

The alarm shall include Tamper Resist Feature. If activated, unit

shall go into constant alarm mode until the unit is replaced into
the wall socket or the battery is removed. In accordance with UL
2034, the CO sensor will not alarm to levels of CO below 30 ppm
and will alarm in the following time range when exposed to the
corresponding levels of CO.

70 ppm CO concentration 60 – 240 minutes
150 ppm CO concentration 10 – 50 minutes
400 ppm CO concentration 4 – 15 minutes

The alarm shall include a piezoelectric horn that is rated at 85

decibels at 10 feet. When the unit detects carbon monoxide, the
alarm pattern will be four (4) short beeps – followed by five (5)
seconds of silence – followed by four (4) short beeps. A number
reading will appear on the digital display identifying the measured
CO concentration (in ppm).

Technical Specifications

Part Number:

900-0234

Model:

KN-COP-DS-LS

Power Source:

120VAC, 60HZ, 60mA max

9V battery back-up

Sensor:

Electrochemical

Audio Alarm:

85dB at 10ft

Temperature Range:

40˚F (4.4˚C) to 100˚F (37.8˚C)

Humidity Range:

10%-95% relative humidity (RH)

Size:

3.0”x 5.6” x 1.5”

Weight:

.62 lbs with battery

Interconnects:

No

Warranty:

7 year limited

Ordering Information

Gift Box UPC: 0-47871-07309-2

*Based on accuracy claims of major manufacturers

**Not for sale by individual unit

Distributed by:

Part

Dimensions

Case/

Skid

Number

I 2 of 5

Pack Quantity

(w x d x h inches)

Weight

Skid

Weight

900-0234**

N/A

Individual (Clam)

7.5 x 2 x 11

1.94 lbs.

N/A

N/A

21007309

100-47871-07309-9

Cutcase (4 units) Clam

7.94 x 11.88 x 11.5

7.76 lbs.

60

465

21007335

200-47871-07309-6

Cutcase (8 units) Clam

7.94 x 21.63 x 11.5

15.52 lbs.

36

558