KODAK VISION3 500T Color Negative Film 5219 / 7219 / SO-219

H-1-5219t

Modulation-Transfer Function Curves

This graph shows a measure of the visual sharpness of

this film. The x-axis, "Spatial Frequency," refers to the
number of sine waves per millimeter that can be resolved.
The y-axis, "Response," corresponds to film sharpness.
The longer and flatter the line, the more sine waves per
millimeter that can be resolved with a high degree of
sharpness—and, the sharper the film.

Diffuse rms Granularity Curves

To find the rms Granularity value for a given density, find

the density on the left vertical scale and follow horizontally
to the characteristic curve and then go vertically (up or
down) to the granularity curve. At that point, follow
horizontally to the Granularity Sigma D scale on the right.
Read the number and multiply by 1000 for the rms value.

Note: This curve represents granularity based on modified
measuring techniques.

4

4. Sensitometric and Diffuse RMS Granularity curves are produced on

different equipment. A slight variation in curve shape may be noticed.

Exposure: 3200K Tungsten

Process: ECN-2
Densitometry: Status M

100

1

2

3 4 5

10

20

50

200

600

SPATIAL FREQUENCY (cycles/mm)

RESPONSE (%)

10

1

2

5

3

7

30

20

100

70
50

200

R

G

B

TI2647B

Process: ECN-2

0.02

0.03

0.04

0.05

0.10

0.005

0.004
0.003

0.002

0.01

0.006

Blue Density
Green Density
Red Density
Blue Grain
Green Grain
Red Grain

GRANULARITY SIGMA D

.001

R

G

R

G

B

B

4.0

5.0

2.0

0.0

1.0

3.0

2.0

1.0

DENSITY

0.0

LOG RELATIVE EXPOSURE

3.0

TI2647C

Spectral Sensitivity Curves

These curves depict the sensitivity of this film to the

spectrum of light. They are useful for determining,
modifying, and optimizing exposure for blue- and
green-screen special-effects work.

Spectral Dye Density Curves

These curves depict the spectral absorptions of the dyes

formed when the film is processed. They are useful for
adjusting or optimizing any device that scans or prints the
film.

Note: Cyan, Magenta, and Yellow Dye Curves are
peak-normalized.

Effective Exposure: 1/25 sec

Process: ECN-2
Densitometry: Status M
Densitry: 0.2>D-min

700

750

650

600

550

500

450

400

350

300

250

*Sensitivity = reciprocal of exposure (erg/cm ) required

to produce specified density

WAVELENGTH (nm)

2

LOG SENSITIVITY

0.0

*

1.0

2.0

3.0

4.0

Yellow-

Forming

Layer

Magenta-

Forming

Layer

Cyan-

Forming

Layer

TI2647D

Process: ECN-2; D-mins subtracted

-0.2

0.2

0.0

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

400

450

500

550

600

650

700

750

800

Yellow

Magenta

Cyan

Minimum Density

Midscale Neutral

DIFFUSE SPECTRAL DENSITY

WAVELENGTH (nm)

TI2647E

This manual is related to the following products: