Calibration Routines for KODAK PROFESSIONAL ENDURA Metallic Paper

Revised 5-06

Printed in U.S.A.

Calibration Routines for KODAK
PROFESSIONAL ENDURA Metallic Paper
KODAK Publication No. CIS-241

CAT 196 2885

Printer

Calibration

OCE LightJet
430, 500XL, 5000

Using Starting D-max values of 2.40R, 2.30G, 2.25B:

1. Go to the Oce website at www.cymbolic.com.

2. Go to Quick Links; Laser Products FTP Site

3. Go to LightJet 430_500XL and 5000

4. Go to LightJet Fusion

5. Choose printer desired

6. Go to Intel

Durst Lambda
130 and 76+

Starting D-max: 2.30R, 2.20G, 2.15B (It is possible to obtain higher D-max in images that do not include text.)
Basic Calibration settings: Y=113.60, M=82.20, C=0.00, D=96.20

Durst Epsilon 30

Starting D-max: 2.30R, 2.15G, 2.15B
Basic Calibration settings: D=0.635, C=0.000, M=0.261, Y=0.359

Durst Theta 76

Starting D-max: 2.25R, 2.20G, 2.15B
Basic Calibration settings: D=1.012, C=0.0, M=0.163, Y=0.361

Durst Theta 50/51 Starting D-max: 2.25R, 2.15G, 2.00B

Basic Calibration settings: D=94.07, C=0.0, M=106.70, Y=184.98

Durst Zeta

Please contact Bill Conger at Durst Dice America, telephone (585) 486-0340, extension 5291.

Fuji Frontier

We recommend that you use KODAK PROFESSIONAL SUPRA ENDURA Paper to calibrate the printer channel that you
plan to use. If you don't have a recommended channel that you normally use, please start testing with Channel I.

1. Load SUPRA ENDURA Paper into the paper magazine that you will use to print.

2. From the Setup and Maintenance menu, select Print Condition Setup and Check. Then select Paper Condition

Setup to perform a standard calibration.

3.

Replace SUPRA ENDURA Paper with ENDURA Metallic Paper.

Noritsu
QSS-2711 and
Noritsu MP1600

Setting up a Channel for KODAK PROFESSIONAL ENDURA Metallic Paper

1. Set up a paper channel with ENDURA Metallic Paper, using the normal Setup procedure. This setup includes MLVA

Setup, Uniformity, and Gamma tests.

2. If any color changes are needed, enter them using the Magazine Balance function on the NORITSU MP1600 printer.

Polielettronica
LASERLAB

1. Set these starting Laser Maximum Density values: Y=200, M=156, C=124.

2. Starting Color Compensation Values Y=0.97, M=0.92, C=1.01.

3. Proceed with the manufacturer's standard paper calibration procedure.

ZBE Chromira 30

Select Kodak on the Emulsion menu, and enter:
Starting D-max: 2.40R, 2.40G, 2.35B
Starting Calibration Values: (C) 3, (M) 0, (Y) -104, (D) 39
Then follow the standard paper calibration procedure.