Venting requirements, Warning – Kenmore ELITE HE3 110.9787 User Manual
Page 9
9
Dryer gas pipe
■
The gas pipe that comes out through the rear of your dryer
has a
³⁄₈" male pipe thread.
*NOTE: If the dryer is mounted on a pedestal, the gas pipe height
must be an additional 10" (25.4 cm) or 15.5" (39.4 cm) from the
floor, depending on the pedestal model. For a garage
installation, the gas pipe height must be an additional
18" (46 cm) from the floor.
Venting Requirements
WARNING:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling or a concealed space of a building.
If using an existing vent system
■
Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.
■
Replace any plastic or metal foil vent with rigid or flexible
heavy metal vent.
■
Review Vent system chart. Modify existing vent system if
necessary to achieve the best drying performance.
If this is a new vent system
Vent material
■
Use a heavy metal vent. Do not use plastic or metal foil vent.
■
4" (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFE™ venting products are recommended.
DURASAFE™ vent products can be purchased from your
dealer. For further information, please call
1-800-4-MY-HOME
®
(1-800-469-4663) or visit our website at
www.sears.com.
Rigid metal vent
■
For best drying performance, rigid metal vents are
recommended.
■
Rigid metal vent is recommended to avoid crushing and
kinking.
Flexible metal vent
■
Flexible metal vents are acceptable only if accessible for
cleaning.
■
Flexible metal vent must be fully extended and supported
when the dryer is in its final location.
■
Remove excess flexible metal vent to avoid sagging and
kinking that may result in reduced airflow and poor
performance.
■
Do not install flexible metal vent in enclosed walls, ceilings or
floors.
Elbows
45° elbows provide better airflow than 90° elbows.
A. ½" NPT gas supply line
B.
³⁄₈
" NPT dryer pipe
A
B
*6¼"
(15.9 cm)
1½"
(3.8 cm)
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
4" (10.2 cm) heavy metal exhaust vent
Good
Better
4"
10.2 cm