beautypg.com

Kenmore ELITE HE3 110.9787 User Manual

Page 11

background image

11

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for
your installation. Two close-clearance installations are shown.
Refer to the manufacturer’s instructions.

NOTE: The following kits for close clearance alternate
installations are available for purchase. For further information,
please call 1-800-4-MY-HOME

®

(1-800-469-4663).

Over-the-Top Installation:

Part Number 26-49900

Periscope Installation (For use with dryer vent to wall vent
mismatch):

Part Number 26-49901 - Less than 5" (12.7 cm) mismatch

Part Number 26-49908 - 5" (12.7 cm) to 18" (45.72 cm)
mismatch

Part Number 26-49904 - 18" (45.72 cm) to 29" (73.66 cm)
mismatch

Part Number 26-49905 - 29" (73.66 cm) to 50" (127 cm)
mismatch

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.

Determine vent path

Select the route that will provide the straightest and most
direct path outdoors.

Plan the installation to use the fewest number of elbows and
turns.

When using elbows or making turns, allow as much room as
possible.

Bend vent gradually to avoid kinking.

Use the fewest 90° turns possible.

Determine vent length and elbows needed for best
drying performance

Use the following Vent system chart to determine type of vent
material and hood combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified in
the Vent system chart. Exhaust systems longer than those
specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and
increased energy usage.

The Vent system chart provides venting requirements that will
help to achieve the best drying performance.

Vent system chart

NOTE: Side and bottom exhaust installations have a 90º turn
inside the dryer. To determine maximum exhaust length, add one
90º turn to the chart.

A. Over-the-top installation (also available with one offset elbow)
B. Periscope installation

A

B

Number of
90º turns
or elbows

Type of
vent

Box or
Louvered
hoods

Angled
hoods

0

Rigid metal
Flexible metal

64 ft (20 m)
36 ft (11 m)

58 ft (17.7 m)
28 ft (8.5 m)

1

Rigid metal
Flexible metal

54 ft (16.5 m)
31 ft (9.4 m)

48 ft (14.6 m)
23 ft (7 m)

2

Rigid metal
Flexible metal

44 ft (13.4 m)
27 ft (8.2 m)

38 ft (11.6 m)
19 ft (5.8 m)

3

Rigid metal
Flexible metal

35 ft (10.7 m)
25 ft (7.6 m)

29 ft (8.8 m)
17 ft (5.2 m)

4

Rigid metal
Flexible metal

27 ft (8.2 m)
23 ft (7 m)

21 ft (6.4 m)
15 ft (4.6 m)

This manual is related to the following products: