beautypg.com

Temperature chart, Troubleshooting – Kenmore 125.15885800 User Manual

Page 15

background image

15

Here is a chart for measuring properly cooked meat
temperature: (USDA Standard)

Ground Meat & Meat Mixtures

Turkey, Chicken

165°

F

(74°

C

)

Veal, Lamb

160°

F

(71°

C

)

Beef, Pork

160°

F

(71°

C

)

Fresh Beef

Medium Rare

145°

F

(63°

C

)

Medium

160°

F

(71°

C

)

Well Done

170°

F

(77°

C

)

Fresh Lamb

Medium Rare

145°

F

(63°

C

)

Medium

160°

F

(71°

C

)

Well Done

170°

F

(77°

C

)

Fresh Veal

Medium Rare

145°

F

(63°

C

)

Medium

160°

F

(71°

C

)

Well Done

170°

F

(77°

C

)

Poultry

Chicken, whole

180°

F

(82°

C

)

Turkey, whole

180°

F

(82°

C

)

Breast, roast

170°

F

(77°

C

)

Thighs, wings

180°

F

(82°

C

)

Duck and Goose

180°

F

(82°

C

)

Fresh Pork

Medium

160°

F

(71°

C

)

Well Done

170°

F

(77°

C

)

Ham

Fresh (raw)

160°

F

(71°

C

)

Pre-Cooked

140°

F

(60°

C

)

Fish

(Cook until opaque and flakes easily)

TEMPERATURE CHART

PROBLEM

Electric
element
will not
heat up

Smoker is
not getting
hot enough

CAUSE

CORRECTION

1. Check that the

3-wire plug is fully
seated into a
3-wire grounded
GFCI outlet wired
for 120 volts and
protected at 15 or
20 amps.

2. Check the break-

ers or fuses for the
outlet being used
are not open or
shorted.

3. Check that the

GFCI outlet has
not been tripped.

4. Electric element

may be damage
and needs

replacing.

1. Adjust temperature

control on electric
element.

2. Avoid the tempta-

tion to check food
too often.

3. Extension cord is

wrong type.

4. Electric element

may be damaged
and needs

replacing.

1. Adjust temperature

control on electric
element.

2. Electric element

may be damaged
and needs

replacing.

1. Reseat plug in a

3-wire grounded
GFCI outlet wired for
120 volts and pro-
tected at 15 or 20
amps.

2. Reset breakers or

replace fuse.

3. Reset GFCI outlet.


4. Replace element.

1. Turn up heat on
control

dial.

2. Opening the door

allows heat to
escape and slows
the cooking process;
open door only when
necessary.

3. Do not use an exten-

sion cord unless ab-
solutely necessary.
Use the shortest
length possible. Use
a 12/3 or 14/3
grounded-type ex-
tension cord with a
rating of at least 15
amps.

4. Replace element.

1. Turn down heat on

control dial.

2. Replace element.

Smoker is
getting
too hot

TROUBLESHOOTING

Note: These temperatures are measured with a meat

probe thermometer. The heat indicator on the
door of the smoker is not an accurate meat
temperature reading.