Warning – Shindaiwa EB212 User Manual
Page 12
12
Eng
lish
A
b
E
s
tartInG
Warm
enGIne
The starting procedure is the same as Cold Start except DO NOT close
the choke.
Stop Switch
Move stop switch button (A) away from the STOP position.
Throttle Position
Move throttle position lever (B) midway between idle and full throttle
positions.
Recoil Starter
Place the unit on a flat clear area. Firmly grasp throttle grip with left
hand and rapidly pull recoil starter handle/rope (E) until engine fires.
IMPORTANT
Recoil starter: Use short pulls - only 1/2-2/3 of rope for starting.
Do not allow the rope to snap back in. Always hold the unit firmly.
NOTE
If engine does not start after 5 pulls, use Cold Start Procedure.
1.
2.
3.
s
toppInG
enGIne
Throttle Trigger/Throttle Position Lever
Release throttle trigger (F). Move throttle position lever (B) forward to
idle position and allow engine to return to idle before shutting engine off.
Stop Switch
Move stop switch (B) to "Stop" position.
WARNING
If engine does not stop when stop switch is moved to STOP position,
close choke - COLD START position - to stall engine. Have your
Shindaiwa dealer repair stop switch before using blower again.
1.
2.
A
F
b