Please check the following before calling for service:

1. Place one cup of water in a glass measuring cup in the oven and close the door securely.
Operate the oven for one minute at MICRO 100%.

A Does the oven light come on?

YES _______ NO _______

B Does the cooling fan work?

YES _______ NO _______

(Put your hand over the rear ventilating openings.)

C Does the turntable rotate?

YES _______ NO _______

(It is normal for the turntable to turn in either direction.)

D Is the water in the oven warm?

YES _______ NO _______

2. Remove water from the oven and operate the oven for 5 minutes at BAKE 400°F.
A Do HEATER and COOK indicators light? YES _______ NO _______
B After the oven shuts off, is inside of the oven hot? YES _______ NO _______

If “NO” is the answer to any of the above questions, please check electrical outlet, fuse and/or circuit breaker.
If they are functioning properly, CONTACT YOUR NEAREST SHARP AUTHORIZED SERVICER.
A microwave oven should never be serviced by a “do-it-yourself” repair person.

NOTE: 1. If time appearing in the display is counting down very rapidly, check DEMONSTRATION MODE on page

22 and cancel.

2. If the oven is set for more than 20 minutes at MICRO 100 percent power level, after the first 20 minutes

the power level will automatically adjust to 70 percent power to avoid overcooking.

3. This oven adjusts GRILL, BAKE and AUTOMATIC COOKING by turning the top and bottom heaters on

and off. It is normal to observe the top heater change from red to dark gray.

4. After cooking is completed, the cooling fan may run for a short time to lower the temperature.

S E R V I C E C A L L C H E C K

The International Electrotechnical Commission’s standardized method for measuring output wattage. This test
method is widely recognized.

★★

Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for holding
food is less.

In compliance with standards set by:

FCC

Federal Communications Commission Authorized.

DHHS

Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I,
Subchapter J.

This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.

S P E C I F I C A T I O N S

Single phase 120V, 60Hz, AC only

980 W 8.5A

1300W 10.8 A

650 W* (IEC Test Procedure)

760 W
510 W

2450 MHz

17-3/4"(W) x 11-3/8"(H) x 15-1/8"(D)

11-1/4"(W) x 5-7/8"(H) x 11-5/8"(D)

Approx. 0.5 Cu. Ft.

Turntable system, 10

1

/

2

" diameter

Approx. 31lb

AC Line Voltage:

AC Power Required:

Microwave

Grill/Bake

Output Power:

Microwave
Top heater

Bottom heater

Frequency:

Outside Dimensions:

Cavity Dimensions

★★

:

Oven Capacity

★★

:

Cooking Uniformity:

Weight: