beautypg.com

Schumacher SPEED CAHRGE SC-8000A User Manual

Page 6

background image

6

NEGATIVE GROUNDED SYSTEM

5. Connecting to a negative-grounded

system: Connect the red (POSITIVE)

output clamp to the POSITIVE post of

the battery. Rock and twist the clamp

back and forth to be sure a solid

electrical connection is made. Then

connect the black (NEGATIVE) output

clamp to a heavy, unpainted metal

part of the chassis or engine block,

away from the battery (see figure).

DO NOT connect clamp to negative

battery post, carburetor, fuel line or

sheet metal part.

Connecting to a positive-grounded

system: Connect the black (NEGA-

TIVE) output clamp to the NEGATIVE

post of the battery. Rock and twist

the clamp back and forth to be sure

a solid electrical connection is made.

Then connect the red (POSITIVE)

output clamp to a heavy, unpainted

metal part of the chassis or engine

block, away from the battery. DO NOT

connect clamp to positive battery

post, carburetor, fuel line or sheet

metal part.

6. Plug power cord into a 120V AC

2-prong wall outlet. The charger will

be set to the default state of 12V

REGULAR battery type, no charge

rate (tester mode). The CONNECTED

LED should be lit. If the CONNECTED

LED is not lit, check for correct cable

connections.

7. Press the appropriate control buttons

to select the desired charge rate and

battery type. Within a few seconds,

the CHARGING (yellow) LED should

light and the charging process should

start.

8. To disconnect the charger, unplug

its power cord before attempting to

disconnect the output clamps. Then,

standing away from the battery, re-

move the output clamp from the chas-

sis or engine block. Finally, remove

the output clamp from the battery

post.

9. Clean and store the charger in a dry

location.

DIGITAL DISPLAY

CHARGING BATTERY REMOVED

FROM THE VEHICLE:

NEGATIVE

BATTERY

CHARGER

BATTERY

24", 6 GAUGE CABLE

POWER

CORD

TO

GROUNDED

POWER

OUTLET

POSITIVE

1. Note the polarity of the battery posts by

checking the identification marks on the

battery: POSITIVE (POS, P or +) and

NEGATIVE (NEG, N or -). The positive

post is usually larger than the negative

post.

2. Attach at least a 24-inch-long, 6-gauge

(AWG), insulated battery cable to

NEGATIVE (NEG, N or -) battery post.

Rock and twist the clamp back and forth

to be sure a solid electrical connection

is made.

3. Connect the red (POSITIVE) output

clamp to the POSITIVE battery post.

Rock and twist the clamp back and forth

to be sure a solid electrical connection

is made.

4. Position yourself as far away from the

battery as possible, and then connect

the black (NEGATIVE) output clamp to

the free end of the cable.

5. Plug the power cord into a 120V AC

2-prong wall outlet. The charger will be

set to the default state of 12V REGULAR

battery type, no charge rate (tester mode).