beautypg.com

Error message table, Before calling for service – Sharp TINSZ2602RCZZ User Manual

Page 81

background image

The malfunctions shown in the left-hand column below, labeled “Problem,” do not necessarily indicate functional
faults of the machine. It is therefore advisable to refer to “Solution” shown in the right-hand column before
calling for service.

Error message table

When the following error messages are displayed, press the

l

key and take a proper action according to the

table below.

Problem

Solution

The display won’t illuminate even when the mode switch
is turned to any other position than “OFF”.

• Is power supplied to the electrical outlet?
• Is the power cord plug out or loosely connected to the
AC outlet?

(2)

The display shows symbols that do not make sense.

• Has the machine been initialized properly as shown in
“GETTING STARTED”?
(Note that initialization clears all the data and programmed
settings stored in memory.)

(1)

The display is illuminated, but the whole machine
refuses registrations.

• Is a clerk code assigned to the register?
• Is the mode switch set properly at the “REG” position?

(3)

No receipt is issued.

• Is the paper roll properly installed?
• Is there a paper jam?
• Is the receipt function in the “OFF” status?
• Is the print head release lever at the printing position?

(4)

No journal paper is taken up.

• Is the take-up spool installed on the bearing properly?
• Is there a paper jam?

(5)

Printing is unusual.

• Is the print head release lever at the printing position?
• Is the paper roll properly installed?

(6)

Before Calling for Service

9

Error message

Error status

Action

ENTRY ERROR

Registration error

Make a correct key entry.

MISOPERATION

Misoperation error

Make a correct key entry.

NO RECORD

Undefined code is entered.

Enter a correct code.

MEMORY FULL

Memory is full (in the

a

key programming).

Program the

a

key within 25 steps.

SBTL COMPUL.

Compulsory depression of the

s

key for

Press the

s

key and continue the operation.

direct finalization

TEND COMPUL.

Compulsory tendering

Make a tendering operation.

NOT ASSIGNED

No entry of a clerk code

Make a clerk code entry.

OVER LIMIT.

Overflow limitation error

Make a registration within a limit of entry.

INH. OPEN PR

The open price entry is inhibited.

Make a preset price entry.

INH. UNIT PR

The preset price entry is inhibited.

Make an open price entry.

NOT NON-TEND

The direct finalization is inhibited.

Make a tendering operation.

BUFFER FULL

Subtotal void is not allowed.

Finalize the transaction, and correct the wrong

entries in the void mode.

HEAD UP

Print head release lever is lifted up.

Move the lever toward the take-up spool (to the

printing position).

PAPER EMPTY

Receipt and/or journal paper roll is not

Install a receipt and/or journal paper.

installed or empty.

79

A406_6 OPERATOR MAINTENANCE 09.10.14 9:08 AM Page 79