11 electromagnetic immunity, 12 reliability – Seagate BARRACUDA ST3250823AS User Manual
Page 24
18
Barracuda 7200.8 Serial ATA Product Manual, Rev. F
2.11
Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:
2.12
Reliability
Table 6:
Radio frequency environments
Test
Description
Performance level
Reference standard
Electrostatic discharge
Contact, HCP, VCP: ± 4
kV; Air:
± 8 kV
B
EN 61000-4-2: 95
Radiated RF immunity
80 to 1,000 MHz, 3 V/m,
80% AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse modulation @
200 Hz
A
EN 61000-4-3: 96
ENV 50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on external I/
O
B
EN 61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common, AC
mains
B
EN 61000-4-5: 95
Conducted RF immunity
150 kHz to 80 MHz, 3 Vrms, 80% AM with
1 kHz sine
A
EN 61000-4-6: 97
Voltage dips, interrupts
0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
C
C
C
B
EN 61000-4-11: 94
Nonrecoverable read errors
1 per 10
14
bits read, max
Annualized Failure Rate (AFR)
0.34% (nominal power, 25°C ambient temperature)
Contact start-stop cycles
50,000 cycles
(at nominal voltage and temperature, with 60 cycles per hour and a 50% duty
cycle)
Service Life
5 years
Warranty
5 years on distribution units.
To determine the warranty for a specific drive, use a web browser to access the
following web page:
www.seagate.com/support/service/
From this page, click on the “Verify Your Warranty” link. You will be asked to pro-
vide the drive serial number, model number (or part number) and country of pur-
chase. The system will display the warranty information for your drive.
Preventive maintenance
None required.