beautypg.com

12 electromagnetic immunity, 13 reliability, Electromagnetic immunity – Seagate U Series 9 CE User Manual

Page 22: Reliability

background image

12

U Series 9 ce Product Manual, Rev. F

*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and

power to operational levels.

2.12

Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:

2.13

Reliability

Table 1:

Fluid Dynamic Bearing (FDB) motor acoustics

Acoustic mode

Models

Idle*

Quiet seek

ST3160022ACE

ST3120025ACE

ST380012ACE

<2.5 bels (typ)

2.7 bels (max)

2.8 bels (typ)

3.0 bels (max)

Test

Description

Performance

level

Reference

standard

Electrostatic discharge

Contact, HCP, VCP:

± 4

kV; Air:

± 8 kV

B

EN 61000-4-2: 95

Radiated RF immunity

80 to 1,000 MHz, 3 V/m,

80% AM with 1 kHz sine

900 MHz, 3 V/m, 50% pulse

modulation @ 200 Hz

A

EN 61000-4-3: 96

ENV 50204: 95

Electrical fast transient

± 1 kV on AC mains, ± 0.5 kV on

external I/O

B

EN 61000-4-4: 95

Surge immunity

± 1 kV differential, ± 2 kV com-

mon, AC mains

B

EN 61000-4-5: 95

Conducted RF immunity

150 kHz to 80 MHz, 3 Vrms,

80% AM with 1 kHz sine

A

EN 61000-4-6: 97

Voltage dips, interrupts

0% open, 5 seconds

0% short, 5 seconds

40%, 0.10 seconds

70%, 0.01 seconds

C

C

C

B

EN 61000-4-11: 94

Nonrecoverable read errors

1 per 10

14

bits read, max.

Mean time between failures

600,000 power-on hours (nominal power, 25°C ambient temperature)

Contact start-stop cycles

50,000 cycles

(at nominal voltage and temperature, with 60 cycles per hour and a 50% duty cycle)

Service Life

5 Years

Preventive maintenance

None required