B400 Installation
2.7
STEREO INPUT REMOTES
Pin
Function
Pin
Function
1
REMOTE START #4 (Ch 4, 8, 12 etc.)
14
REMOTE START #3 (Ch 4, 8, 12 etc.)
2
REMOTE STOP #4 (Ch 4, 8, 12 etc.)
15
REMOTE STOP #3 (Ch 4, 8, 12 etc.)
3
REMOTE START #4 (Ch 3, 7, 11 etc.)
16
REMOTE START #3 (Ch 3, 7, 11 etc.)
4
REMOTE STOP #4 (Ch 3, 7, 11 etc.)
17
REMOTE STOP #3 (Ch 3, 7, 11 etc.)
5
REMOTE START #4 (Ch 2, 6, 10 etc.)
18
REMOTE START #3 (Ch 2, 6, 10 etc.)
6
REMOTE STOP #4 (Ch 2, 6, 10 etc.)
19
REMOTE STOP #3 (Ch 2, 6, 10 etc.)
7
REMOTE START #4 (Ch 1, 5, 9 etc.)
20
REMOTE START #3 (Ch 1, 5, 9 etc.)
8
REMOTE STOP #4 (Ch 1, 5, 9 etc.)
21
REMOTE STOP #3 (Ch 1, 5, 9 etc.)
9
Not used
22
Not used
10
Not used
23
Not used
11
Not used
24
Not used
12
Not used
25
Not used
13
Not used
NOTE: Each input slot may be fitted with a Mono or Stereo module, and the pinouts for the last two connec-
tors may therefore be a combination of the two versions on some frames.
EXT LOGIC
Pin
Function
Pin
Function
1
GND
14
GND
2
GND
15
Prod T/B Stud CTL
3
Prod T/B to Ext CTL (I/P)
16
Ext mute I/P (studio spkr)
4
Prod T/B to Eng CTL (I/P)
17
Talk to Ext CTL O/P
5
Option 2 - CTL #2
18
Option 2 - CTL #1
6
Option 1 - CTL #2
19
Option 1 - CTL #1
7
On-Air o/p #
20
On-Air O/P #2
8
On-Air i/p #1
21
On-Air I/P #2
9
Not Used
22
Not Used
10
Ext Mntr (Level CTL I/P)
23
Ext CUE (Level CTL I/P)
11
RET T/B CTL (I/P)
24
Ext A/B CTL R (I/P)
12
Ext A/B CTL L (I/P)
25
Ext mute R (I/P)
13
Ext mute L (I/P)
METERBRIDGE
This connects via a ribbon cable to the Monitor/Comms D-type on the meterbridge.
1
Not used
14
Not used
2
ST Mntr/Meter
15
ST Mntr/Meter
3
MONO Mntr/Meter
16
MONO Mntr/Meter
4
not used
17
not used
5
not used
18
not used
6
Not Used
19
GND
7
TB Mic
20
TB Mic +1V5
8
Studio Meter R
21
Studio Meter L
9
Ext VCA Warning LED
22
Monitor Meter L
10
Monitor Meter R
23
O/Press Meter
11
O/Press Ctl
24
Squawk Feed
12
Cue Meter R
25
Cue Meter L
13
Cue Ctl