Electrical connection, Instructions for the installer – Smeg Cooking Hob P106 User Manual
Page 5
Instructions for the installer
22
3. Electrical connection
Make sure that the voltage and capacity of the power line conform to the data shown
on the plate located under the casing. Do not remove this plate for any reason.
The plug on the end of the supply cable and the wall socket must be the same type
and conform to the current electrical system regulations. Check that the power line is
adequately grounded.
Pass the power supply cable through the back of the unit, taking care that it does not
touch the bottom casing of the hob or the oven (if any) installed underneath it.
On the power line, install an omnipolar cut-off device with contact cut-off distance
greater than or equal to 3 mm, located in an easily accessible position near the unit.
Do not use reducers, adapters or shunts.
If the power cable is replaced, the wire section on the new cable must not be less than
0.75 mm
2
(3 x 0.75 cable), keeping in mind that the end to be connected to the hob
must have the ground wire (yellow-green) longer by at least 20 mm. Use only
H05V2V2-F cable or similar which has a maximum temperature of 90°C. Any replacement
needed should be carried out by a specialised technician who should make the mains
connections according to the following diagram.
L = brown
N = blue
= yellow-green
The power lead must be changed by the manufacturer or by an authorised service
centre to prevent any risks.
The manufacturer will not be liable for any damage to persons or property caused by
non-observance of the above instructions or deriving from the tampering of even a
single part of the hob.