beautypg.com

11 electromagnetic immunity, 12 reliability, Electromagnetic immunity – Seagate BARRACUDA ST3320413AS User Manual

Page 23: Reliability

background image

Barracuda SATA Product Manual, Rev. B

23

www.seagate.com

Drive Specifications

2.11 Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following

Table 7

:

2.12 Reliability

The product shall achieve an Annualized Failure Rate (AFR) of 0.34% (MTBF of 0.75 million hours) when operated
in an environment of ambient air temperatures of 25

°

C. Operation at temperatures outside the specifications in

Section 2.9 may increase the product AFR (decrease MTBF). AFR and MTBF are population statistics that are not
relevant to individual units.

AFR and MTBF specifications are based on the following assumptions for desktop personal computer
environments:

• 2400 power-on-hours per year.

• 10,000 average motor start/stop cycles per year.

• Operations at nominal voltages.

• Temperatures outside the specifications in Section 2.9 may reduce the product reliability.

• Normal I/O duty cycle for desktop personal computers. Operation at excessive I/O duty cycle may degrade

product reliability.

The desktop personal computer environment of power-on-hours, temperature, and I/O duty cycle affect the product
AFR and MTBF. The AFR and MTBF will be degraded if used in an enterprise application

Table 7

Radio frequency environments

Test

Description

Performance
level

Reference
standard

Electrostatic discharge

Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV

B

EN61000-4-2: 95

Radiated RF immunity

80MHz to 1,000MHz, 3 V/m,

80% AM with 1kHz sine

900MHz, 3 V/m, 50% pulse modulation @
200Hz

A

EN61000-4-3: 96

ENV50204: 95

Electrical fast transient

± 1 kV on AC mains, ± 0.5 kV on external I/O B

EN61000-4-4: 95

Surge immunity

± 1 kV differential, ± 2 kV common,
AC mains

B

EN61000-4-5: 95

Conducted RF
immunity

150kHz to 80MHz, 3 Vrms, 80% AM with
1kHz sine

A

EN61000-4-6: 97

Voltage dips, interrupts

0% open, 5 seconds

0% short, 5 seconds

40%, 0.10 seconds

70%, 0.01 seconds

C

C

C

B

EN61000-4-11: 94

Nonrecoverable read errors

1 per 10

14

bits read, max

Annualized Failure Rate (AFR)

0.34% (nominal power, 25°C ambient temperature)

Contact start-stop cycles

50,000 cycles

(at nominal voltage and temperature, with 60 cycles per hour and a 50% duty cycle)

Preventive maintenance

None required.