Model 2050/2060

Ammonia and Halocarbon Gas Monitors

SPECIFICATIONS

Indicators:

Green LED for Monitor “ON”/Safe
Red LED for Alarm

Sensor Type:

Solid-state metal oxide semiconductor

Alarm Setpoint::

2050 Series

100 ppm NH

3

2060 Series

R11

500 ppm

R12

500 ppm

R22

50 ppm

R113

100 ppm

R123

70 ppm

R134a

50 ppm

R141b

40 ppm

R142b

40 ppm

R500

40 ppm

R502

70 ppm

User adjustable with calibration over
range of 50 to 500 ppm

Calibration Gas:
2050 Series

80 ppm Hydrogen (H

2

)

2060 Series

150 ppm Carbon Monoxide (CO)

Power:

9-24 VDC, 250 mA

Signal Output::
2050-00/2060-00

Nominal 5 volt DC, source 25 mA. SAFE
and ALARM Signals
0.5 AMP dry contact, 100 VDC, 130 VAC
and audible

Response Time:

Less than 90 seconds

Operating Temperature Range:

-4

o

to 158

o

F (-20

o

to 70

o

C)

Enclosure Material:

Polystyrene

Size:

5.6 x 3.1 x 2.1 in. (14.2 x 7.9 x 5.3

cm)

Weight:

0.3 lb (0.15 Kg)

Sierra Monitor Corporation 1991 Tarob Court Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 FAX: (408) 262-9042

Visit our website: www.sierramonitor.com E-mail: [email protected]

Outline and Dimensions

of Model 2050/2060

ORDERING INFORMATION

2050-00

Ammonia Gas Monitor

2060-00

Refrigerant/Halocarbon Gas Monitor

1200-26

Gas Sensor Calibrator w/2 gas cylinders
of calibration gas

1290-10

Gas Cylinder - Carbon Monoxide, 150 ppm

1290-11

Gas Cylinder - Hydrogen, 80 ppm

OTHER PRODUCTS

2102-00

Dual Channel Alarm Panel

© 2010 Sierra Monitor Corp. Rev. A-7/10