beautypg.com

Instructions for the installer, 2 burner and nozzle characteristics table, 3 arrangement of burners on cooking hob – Smeg A21A0XXAA User Manual

Page 9

background image

Instructions for the installer

24

3.2 Burner and nozzle characteristics table

Burner

Rated

heating

capacity

(kW)

LPG – G30/G31 28/37 mbar

Nozzle

diameter

1/100 mm

By-pass

mm

1/100

Reduced

flowrate

(W)

Flowrate

g/h G30

Flowrate

g/h G31

Auxiliary (1)

1.05

50

30

350

76

75

Semi rapid (2)

1.8

65

33

450

130

128

Rapid (3)

2.3

75

45

800

166

164

Ultrarapid (3)

3.5

94

65

1.6

253

250

Burner

Rated

heating

capacity

(kW)

Natural gas – G20 20 mbar

Nozzle diameter

1/100 mm

Reduced flowrate

(W)

Auxiliary (1)

1.05

72

350

Semi rapid (2)

1.8

97

450

Rapid (3)

2.3

103

800

Ultrarapid (4)

3.5

133

1500

3.3

Arrangement of burners on cooking hob

BURNERS

1

Auxiliary

2

Semi rapid

3

Rapid

4

Ultrarapid