Spectra Watermakers Newport 400 User Manual
Page 10
10
The membrane maximum temperature specification is 120F. This module must be installed in
an area that maintains a temperature below 120F (50C). A cool location is preferable. It may
be placed as high in the boat as you desire. Make sure that the area around and under the pump
does not have any water sensitive equipment. Water will be spilled during any repairs or if a
leak occurs.
Be sure you will have access to the pressure relief valve on the Clark pump.
The Clark pump/membrane module comes complete with a mounting system. Be sure to use the
supplied washers on the rubber feet. Use it as a template for drilling the mount holes. You may
mount the Clark Pump in any position, even upside down.
The Clark pump and membrane assembly has been pre-assembled at the factory. If it is nec-
essary to disassemble this module and mount the pressure vessel remotely use guidelines in
back of the manual. Use only approved tubing for assembly.
Clark Pump/Membrane Module
Membrane Pressure Vessel Mounting
Pressure Relief Valve