Instructions for the installer, 2 regulation for lpg – Smeg SDR60XG User Manual

Page 10

background image

Instructions for the installer

5.2

Regulation for LPG

Loosen screw A and push support B all the way. Use a double head
wrench to remove nozzle C and assemble the suitable one, following the
instructions indicated in the reference charts, with respect to the type of
gas to use. The screwing torque of the nozzle should never exceed
3 Nm. Reposition support B so that nozzle C is covered perfectly.
Move the Venturi tube D to regulate the air flow until distance "X" is
reached indicated in the chart in paragraph "5.4 Regulation of primary air”
and then secure the tube by means of screw A. After the regulations
have been carried out, restore the seals with sealing wax or equivalent
material.
















Burner

Rated

heating

capacity

(kW)

LPG – G30/G31 28/37 mbar

Nozzle

diameter

1/100 mm

By-pass

mm

1/100

Reduced

flowrate

(W)

Flowrate

g/h G30

Flowrate

g/h G31

Auxiliary (1)

1.05

48

30

33 (*)

380

76

75

Semi-rapid (2)

1.65

62

30

33 (*)

380

120

118

Rapid (3)

2.55

76

37

40 (*)

650

185

182

Rapid (4)

3.1

85

43

45 (*)

750

225

222

Ultra rapid (5)

3.9

95

65

1600

283

279


(*) By-pass value for valveless appliances.