beautypg.com

Sears KENMORE 625.34845 User Manual

Page 7

background image

WATER SOFTENER START-UP

SECTION 1

7

1C.

PROGRAM THE TIMER

2. SET WATER HARDNESS NUMBER:

Press the SELECT button once to display 15

(flashing) and HARDNESS.
The grains per gallon (gpg)

hardness of your water supply is

on your water analysis report. Be

sure to enter water test results on

page 2, for future reference.

NOTE:

If your water supply contains iron, compensate for

it by adding to the water hardness number. For

example, assume your water is 15 gpg hard and

contains 2 ppm iron. Add 5 to the hardness

number for each 1 ppm of iron. In this example,

you would use 25 for your hardness number.

15 gpg hardness

2 ppm iron x 5 = 10

+10

(times)

25 HARDNESS NUMBER

Press the

UP/DOWN

buttons to set your

water hardness number in the display. The

DOWN button moves the display to 1. The UP

button moves the display to the highest setting

(see maximum setting for your model in the

specifications).

NOTE:

Each press of the UP/DOWN button changes the

display by 1 between 1 and 25. Between 25 and

the highest number, the display changes 5 at a

time

25, 30, 35, etc. Continuous pressure on the

UP or DOWN button changes the display twice

each second.

3. SET RECHARGE (REGENERATION) TIME:

Press the SELECT button once to display 2:00

AM (flashing) and RECHARGE TIME.
At the 2:00 AM RECHARGE TIME

setting, the softener begins reĆ

generation (see pages 11 and 12)

at 2:00 AM, ending no later than

4:00 AM. This is a good time in

most households because water

is not being used (see AUTOĆ

MATIC BYPASS, page 13).
If a different RECHARGE TIME setting would be

better for your household, do the following.

Press the

UP/DOWN

buttons to set the

desired RECHARGE starting hour. Be sure to

observe the AMĆPM as you did when setting the

time of day.

NOTE:

Each press of the UP/DOWN buttons changes the

display 1 hour. Continuous pressure on the UP or

DOWN button changes the display twice each

second.

Press the SELECT button once again, to

return the present time (steady) of day and

RECHARGE TONIGHT in the display.

IF YOU NEED HELP PROGRAMMING THE TIMER, CALL TOLL FREE, NUMBER 1-800- 426- 9345.

SEE PAGE 10 FOROTHERFACE PLATE TIMERFEATURES.

This manual is related to the following products: