background image

SERVICE TECH. INFORMATION

SECTION 5

21

5A.

TROUBLESHOOTING

CORRECT

SWITCH

DISPLAYS

VALVE CYCLE STATUS

– –

Valve in service, fill, brining, back-
wash or fast rinse position

– P

Valve rotating from one position to
another

C. While in this diagnosticscreen, the following

information is available and may be beneficial

for various reasons. This information is reĆ

tained by the computer from the first time elecĆ

trical power is applied to the face plate.
-- Press

to display the number of days this

face plate has had electrical power applied.
-- Press

to display the number of regenĆ

erations initiated by this face plate since the SR

code number was entered.

2. Press the SELECT button and hold 3 seconds

until

This code identifies the softener nominal capacity

size. If the wrong number shows, the softener will

operate on incorrect programming. Do the

following as needed.
Return the present time display: Press the

SELECT button.
Change the SR number: Press the

UP or

DOWN button to display correct number. Press

SELECT, and reset the timer.

NOTE:

If the face plate is left in a diagnostic display (or a flashing

display when setting times or hardness), present time

automatically returns if a button is not pressed within 4

minutes.

FACE PLATE REPLACEMENT: Be sure the valve is in

service position (observe valve cycle indicator)

when replacing the face plate.

If, after installing and programming the replacement face

plate, the valve is not in service position, do the followĆ

ing to assure correct cycle orientation, or timing, beĆ

tween the face plate and valve.

Use the MANUAL ADVANCE procedures, page 22. With

the RECHARGE NOW button, advance through the reĆ

charge cycles until the valve stops in service position,

and RECHARGE no longer flashes in the timer.

NOTE: The valve motor may automatically drive through

several valve positions while searching for service. If an

error code occurs, unplug the transformer, then plug in

again

CAM

MOTOR

position
markers