beautypg.com

Instructions for the installer, 3 regulation for natural gas, 4 regulation of primary air – Smeg ER12550NL User Manual

Page 10: Referred to distance “ x ” in mm

background image

Instructions for the installer

27

5.3 Regulation for natural gas

The hob has been inspected for G20 (2H) natural gas at a pressure of
20 mbar. To allow the unit to work with this type of gas, perform the same
operations described in paragraph “5.2 Regulation for LPG”, but choose
the nozzles and regulate the primary air for natural gas, as shown in the
following table and in paragraph “5.4 Regulation of primary air”. After the
regulations have been carried out, restore the seals with sealing wax or
equivalent material.


Burner

Rated heating

capacity

(kW)

Natural gas – G20 20 mbar

Nozzle diameter

1/100 mm

Reduced flowrate

(W)

Auxiliary (1)

1.05

73

380

Triple crown (2)

3.3

130

1200

internal (3)

0.8

115

380

Double crown

external (3)

3.3

250

1200



5.4 Regulation of primary air

Referred to distance “X” in mm.


BURNER

G20

20 mbar

G30/G31

28/37 mbar

Auxiliary (1)

1.5

2

Triple crown (2)

1.5

3

internal (3)

8.5

9

Double crown

external (3)

1

9

This manual is related to the following products: