beautypg.com

2 standard ata commands – SimpleTech Zeus Ultra User Manual

Page 28

background image

Functional Description

ATA Commands

22

Zeus Ultra DMA Solid State Drives

2.4.2

Standard ATA Commands

Table 7 lists each command along with its respective command code and registers
accessed by the command. For detailed descriptions of the ATA commands, refer to the
ATA-5 specification.

Table 7.

Supported ATA Commands

Command

Command

Code (Hex)

Feature

Register

Sector

Count

Register

Sector

Number

Register

Cylinder

High/Low

Register

Drive/Head

Number

Register

CHECK POWER MODE

98 or E5

No

Yes

No

No

Yes

a

a.

Only drive parameters are valid.

ERASE SECTOR

C0

No

Yes

Yes

Yes

Yes

b

b.

Drive and head parameters are valid.

EXECUTE DRIVE

DIAGNOSTIC

90

No

No

No

No

Yes

c

c.

Address to drive 0 (zero). When executed, Both drives (master and slave) execute this command).

FORMAT TRACK

50

No

Yes

No

Yes

Yes

(b)

IDENTIFY DRIVE

EC

Yes

No

No

No

Yes

(a)

IDLE

97, E3

No

Y

No

No

Yes

(a)

IDLE IMMEDIATE

95, E1

No

No

No

No

Yes

(a)

INITIALIZE DRIVE
PARAMETERS

91

No

Yes

No

No

Yes

(b)

READ MULTIPLE

C4

No

Yes

Yes

Yes

Yes

(b)

READ SECTOR(S)

20

No

Yes

Yes

Yes

Yes

(b)

READ VERIFY SECTOR(S)

40

No

Yes

Yes

Yes

Yes

(b)

RECALIBRATE

10

No

No

No

No

Yes

(a)

SEEK

70 - 7F

No

No

Yes

Yes

Yes

(b)

SET FEATURES

EF

No

Yes

Yes

Yes

Yes

(b)

SET MULTIPLE MODE

C6

No

Yes

No

No

Yes

(a)

SET SLEEP MODE

99 or E6

No

No

No

No

Yes

(a)

STANDBY

96 or E2

No

Yes

No

No

Yes

(a)

STANDBY IMMEDIATE

94 or E0

No

No

No

No

Yes

(a)

WRITE MULTIPLE

C5

No

Yes

Yes

Yes

Yes

(b)

WRITE SECTOR(S)

30

No

Yes

Yes

Yes

Yes

(b)