beautypg.com

Peration, Erformance, Haracteristics – SimpleTech Zeus Ultra User Manual

Page 16

background image

Product Description

Operation and Performance Characteristics

10

Zeus Ultra DMA Solid State Drives

1.6.2

Power Consumption

The amount of power consumed by Zeus SSDs is determined by the storage (memory)
capacity of the drive, and the flash controller/memory configuration of the drive. Table 3
lists (by capacity) the power consumption of Zeus SSDs during typical operations at 5
Vdc.

1.7

O

PERATION

AND

P

ERFORMANCE

C

HARACTERISTICS

1.7.1

ATA (IDE) Bus Modes

Zeus SSDs support the following ATA operating modes:

PIO Modes 0 through 4

Ultra DMA Modes 0 through 4

1.7.2

Mount Time

The amount of time required to initialize and mount a Zeus SSD varies, depending on the
operating system (Windows

®

, Linux

®

, etc.) in which the SSD is running and the storage

capacity of the drive.

1.7.3

Seek Time

Unlike a magnetic rotating disk, the Zeus SSD has no moving head or platter. There is
no seek time or rotational latency issues to contend with. Zeus SSDs dramatically
improve transaction throughput, particularly for applications that are configured to take
advantage of the characteristics of the drive.

Table 3.

Zeus SSD Typical Power Consumption (watts/mA)

8 GB

a

a.

10-40 MB/sec

16 GB

a

24 GB

a

32 G

a

72 GB

b

b.

10-60 MB/sec

Sustained Read/

Write

2.50 watts/
431 mA

2.15 watts/
431 mA

2.15 watts/
431 mA

2.15 watts/
502 mA

3.63 watts/
726 mA

c

c.

Estimated value

Sanitized Erase/Fill

(running low power option)

3.00 watts/

600 mA

2.92 watts/

583 mA

3.38 watts/

675 mA

3.71 watts/

741 mA

7.43 watts/

1485 mA

c