Page 10

Instructions for the installer
2.5 Discharge of combustion products
Discharge of combustion products must be guaranteed by means of 
hoods connected to a natural draught flue with certain efficiency, or by 
means of forced aspiration. 
An efficient aspiration system requires careful planning by a specialist 
capable of installing it, respecting the positions and distances prescribed 
by standards. After installation, the installer must issue a certificate of 
conformity. 
 
3. GAS CONNECTION 
This appliance is suitable for installation with 
Natural Gas or LPG (propane). Refer to page 12 
for the relevant burner pressure and appropriate 
injector sizes. When the appliance is to be 
connected to Natural Gas then the pressure 
regulator supplied must be fitted to the gas inlet. A 
test point (for checking the gas pressure) is 
supplied either with the regulator or as a separate 
fitting in the case of LPG (propane) appliances. 
Connection of the appliance to the gas supply 
must be in accordance with the requirements of 
AS5601. A ½” BSP connector at the inlet is 
recommended and the gas supply line to the 
appliance must be of adequate length to allow 
sufficient withdrawal of appliance for service or 
disconnection and be annealed copper 
pipe.
trewqertttt
The appliance must be installed with provision to allow the gas to be 
turned off and disconnected for servicing and removal of the appliance 
as required from the gas supply. 
Before the appliance is operated make certain all relevant parts are 
placed in the correct position. 
When the installation is completed the installation connections of 
appliance will require to be leak tested, the burner operating pressure 
and flame checked and adjusted. 
Warranty service calls do not cover these adjustments! 
To check the operating pressure of the appliance it is recommended at 
least 2 large size burners are used. Ensure appliance is secured to wall 
when installation is completed. 
N.G. The regulator supplied must be fitted to the ½ BSP thread at the 
rear of the appliance. An approved manual shut-off valve must be 
installed. The N.G. regulator must be checked and adjusted to 1.0kPa 
after installation. 
12