Sears 12V Battery Charger & Engine Starter 2871222 User Manual
Page 12
•
10
•
PROBLEM
POSSIBLE CAUSE
REASON/SOLUTION
The charger is making an
audible clicking sound.
Circuit breaker is cycling.
Battery is defective.
Shorted battery cables or
clips.
Severely discharged battery,
but otherwise it is a good
battery.
Reverse connections at
battery.
The settings may be wrong.
Check the charger settings.
Have the battery checked.
Circuit breaker cycles when
current draw is too high.
Check for shorted cables or
clips and replace if necessary.
The battery may not want to
accept a charge due to a run-
down state. Allow charging to
continue until battery has a
chance to recover sufficiently
to take a charge. If more than
20 minutes, stop charging and
have the battery checked.
Shut the charger off and
correct the lead connections.
Charger makes a noticable
buzz or hum.
Transformer laminations
vibrate (buzz).
No problem, this is a normal
condition.
Short or no start cycle when
cranking engine.
Drawing more than 50 amps.
Failure to wait 3 minutes
between cranks.
Clips are not making a good
connection.
AC cord and/or extension
cord is loose.
No power at receptacle.
The charger may be
overheated.
Battery may be severely
discharged.
Crank time varies with the
amount of current drawn. If
cranking draws more than 50
amps, crank time may be less
than 10 seconds.
Wait 3 minutes of rest time
before the next crank.
Check for poor connection at
battery and frame.
Check power cord and
extension cord for loose fitting
plug.
Check for open fuse or circuit
breaker supplying AC outlet.
The thermal protector may
have tripped and needs a little
longer to reset. Make sure the
charger vents are not blocked.
Wait and try again.
On a severely discharged
battery, charge for 10 to 15
minutes in the 10 amp manual
rate to help assist in cranking.
The measured current is
much lower than what was
selected.
The charger reached the
maximum voltage and is
reducing the current.
No problem, this is a normal
condition.