NO
ITEMS
TEST CONDITION
PERFORMANCE
16
MOISTURE
RESISTANCE
THE CAPACITOR SHALL BE STORED AT A
TEMPERATURE OF 40±2℃ AND RELATIVE
HUMIDITY OF 90% TO 95% FOR 500±8 HOURS.
ELECTRICAL MEASUREMENTS SHALL BE MADE
AFTER BEING BOARD AT ROOM TEMPERATURE
FOR 1∼2 HOURS. FOR OTHER PROCEDURES
REFER TO IEC Pub. 68-2-2.
CHANGE IN CAPACITANCE :
WITHIN : ±10% OF THE
INITIAL VALUE
TANGENT OF LOSS ANGLE :
LEAKAGE CURRENT :
17
LOAD LIFE
THE CAPACITOR SHALL BE PLACED IN A
CIRCULATING AIR OVEN AT AN AMBIENT.
ELECTRICAL MEASUREMENTS SHALL BE MADE
AFTER BEING STORED AT ROOM TEMPERATURE
FOR 1~2 HOURS.
CHANGE IN CAPACITANCE :
WITHIN : ±10% OF THE
INITIAL VALUE
TANGENT OF LOSS ANGLE :
LEAKAGE CURRENT :
18
STORAGE AT
LOW
TEMPERATURE
THE CAPACITOR SHALL BE STORED AT A
TEMPERATURE OF -55±2℃ FOR 240±8 HOURS
WITHOUT LOAD.
ELECTRICAL MEASUREMENTS SHALL BE MADE
AFTER BEING STORED AT ROOM TEMPERATURE
FOR 1~2 HOURS
ELECTRICAL
CHARACTERISTICS SHALL
SATISFY THE INITIAL
REQUIREMENT.
19
Thermal Shock
THE CAPACITOR SHALL BE SUBJECTED TO EACH
SPECIFIED TEMPERATURE FOR EACH SPECIFIED
TIME IN THE TABLE ABOVE
THESE 4 STEP CONSTITUTES ONE CYCLES SHALL
BE PERFORMED CONTINUOUSLY
CHANGE IN CAPACITANCE :
WITHIN : ±10% OF THE
INITIAL VALUE
TANGENT OF LOSS ANGLE :
LEAKAGE CURRENT :
STEP
TEMPERATURE
TIME
1
-55
℃
30 ±3 MIN
2
25 ± 5℃
15 ±2 MIN
3
125
℃
30 ±3 MIN
4
25 ± 5℃
15 ±2 MIN
0
-3
0
-3
TEMPERATURE
VOLTAGE
TIME
85℃
RATED VOLTAGE
2,000 HOURS
125℃
DERATED
VOLTAGE
2,000 HOURS