SCL Series

NO

ITEMS

TEST CONDITION

PERFORMANCE

16

MOISTURE

RESISTANCE

THE CAPACITOR SHALL BE STORED AT A
TEMPERATURE OF 40±2℃ AND RELATIVE
HUMIDITY OF 90% TO 95% FOR 500±8 HOURS.
ELECTRICAL MEASUREMENTS SHALL BE MADE
AFTER BEING BOARD AT ROOM TEMPERATURE
FOR 1∼2 HOURS. FOR OTHER PROCEDURES
REFER TO IEC Pub. 68-2-2.

CHANGE IN CAPACITANCE :
WITHIN : ±10% OF THE
INITIAL VALUE
TANGENT OF LOSS ANGLE :

LEAKAGE CURRENT :

17

LOAD LIFE

THE CAPACITOR SHALL BE PLACED IN A
CIRCULATING AIR OVEN AT AN AMBIENT.
ELECTRICAL MEASUREMENTS SHALL BE MADE
AFTER BEING STORED AT ROOM TEMPERATURE
FOR 1~2 HOURS.

CHANGE IN CAPACITANCE :
WITHIN : ±10% OF THE
INITIAL VALUE
TANGENT OF LOSS ANGLE :

LEAKAGE CURRENT :

18

STORAGE AT

LOW

TEMPERATURE

THE CAPACITOR SHALL BE STORED AT A
TEMPERATURE OF -55±2℃ FOR 240±8 HOURS
WITHOUT LOAD.
ELECTRICAL MEASUREMENTS SHALL BE MADE
AFTER BEING STORED AT ROOM TEMPERATURE
FOR 1~2 HOURS

ELECTRICAL
CHARACTERISTICS SHALL
SATISFY THE INITIAL
REQUIREMENT.

19

Thermal Shock

THE CAPACITOR SHALL BE SUBJECTED TO EACH
SPECIFIED TEMPERATURE FOR EACH SPECIFIED
TIME IN THE TABLE ABOVE
THESE 4 STEP CONSTITUTES ONE CYCLES SHALL
BE PERFORMED CONTINUOUSLY

CHANGE IN CAPACITANCE :
WITHIN : ±10% OF THE
INITIAL VALUE
TANGENT OF LOSS ANGLE :

LEAKAGE CURRENT :

STEP

TEMPERATURE

TIME

1

-55

30 ±3 MIN

2

25 ± 5℃

15 ±2 MIN

3

125

30 ±3 MIN

4

25 ± 5℃

15 ±2 MIN

0

-3

0

-3

TEMPERATURE

VOLTAGE

TIME

85℃

RATED VOLTAGE

2,000 HOURS

125℃

DERATED

VOLTAGE

2,000 HOURS